激光跟踪系统隐藏特征测量探头不对称误差校准

来源 :ChineseOpticsLetters | 被引量 : 0次 | 上传用户:beibei114
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
A technique to calibrate faro retro probe using laser tracker system (LTS) is presented. The deep-access retro probe enables LTS to perform three-dimensional (3D) measurements of surface hidden features. It has been shown that misalignment errors are the key contributor to measuring errors of retro probe. A device for measuring misalignment errors of retro probe is invented. Theoretical analysis and experiment show that using this technique to calibrate retro probe, the misalignment errors of retro probe can be eliminated effectively and quickly.
其他文献
A Yb-doped silica glass fiber laser with a core made by sol-gel method is reported. The maximum power of 1.14 W is obtained with a pump power of 5.46 W at a wavelength of 976 nm. The slope efficiency is 34%. The refractive index fluctuation across the cor
利用大偏置熔接方法在两段单模光纤(SMF)中间熔接一小段单模光纤作为支撑梁制作了一种开腔式法布里珀罗(F-P)干涉传感器。提出在干涉腔内填充一种湿度敏感型物质聚丙烯酰胺(PAM)从而形成一种高灵敏度的微型湿度计。当PAM通过吸收空气中的水蒸气而引起自身折射率发生改变,从而导致F-P干涉谱发生漂移,通过检测干涉谱的漂移量可以实现对环境相对湿度的测量。实验结果表明,这种湿度传感器在38%~78%的相对湿度范围内,在PAM折射率变化范围内其干涉谱漂移了约4 nm,漂移量与相对湿度的灵敏度约为0.1 nm/%;而
We describe a polarization rotator based on a parallel-core structure consisting of a silicon nanowire waveguide and a silicon-nitride waveguide. The 60-μm-long rotator provides a polarization extinction ratio of more than 10 dB with excess loss of less t
期刊
星载气辉成像干涉仪采用临边观测模式, 可以获取全球范围内大气风场的空间分布信息及时间演化信息, 是国际卫星遥感领域的研究热点。基于O3辐射源的Michelson星载成像干涉仪在红外波段工作, 能够全天时探测平流层区域的大气风场, 却存在更为复杂的测风不确定度。鉴于此, 在临边观测正演仿真的基础上, 开展了仪器热背景辐射研究及测量噪声分析, 给出了大气信号测量噪声及仪器热背景噪声引起的大气风场速度误差数值, 并通过表观量仿真及信噪比分析, 得到了视向风的误差廓线。不确定度分析表明, 基于O3辐射源的Mich
Optical links are moving to higher and higher transmission speeds while shrinking to shorter and shorter ranges where optical links are envisaged even at the chip scale. The scaling in data speed and span of the optical links demands modulators to be conc
We investigate the superposition properties of the dipole and quadrupole plasmon modes in the near field both experimentally, by using photoemission electron microscopy (PEEM), and theoretically. In particular, the asymmetric near-field distributions on g
在87Rb冷原子系综中,利用自发Raman散射过程实现了光与原子纠缠。通过选择两个不同的跃迁频率的读光对存储的自旋波进行读出,在两种不同读光频率下测量了读出效率以及Bell参数S值。结果发现在读光功率相同的条件下其中一种读光频率的读出效率为18%,Bell参量S值为2.68。另一种读光频率的读出效率达到38%,Bell参量S值为2.5。本文的研究成果为产生高质量的光与原子纠缠源提供了实验基础。
本文叙述采用输出波长为308nm的XeCl准分子激光器进行微米级接触式光刻实验.获得1.5μm的分辨线条,而2.25μm线条已符合集成电路光刻要求.
期刊
期刊