论文部分内容阅读
A new adsorbent QCR was prepared with quinine impregnated on cation exchange resin. It was found that QCR was stable in the solution of HCl(0.1~3.0 mol/L). Separation and preconcentration of noble metal ions (Au、Pd、Pt) by QCR have been studied by Inductively Coupled Plasma Atomic Emission Spectronetry (ICP|AES). More than 93% of noble metal ions were adsorbed by QCR in 0.1mol/L HCl; and the analyte could be eluted quantatively by using 2 g/L thiourea -0.1 mol/L HCl as the eluant. The adsorption selectivity to Au、Pd、Pt is good at the existence of some non|noble ions. This method has been applied to the analysis of catalysts and anticancer drugs with satisfactory results.;
A was first adsorbed QCR was prepared with quinine impregnated cation exchange resin. It was found that QCR was stable in the solution of HCl (0.1 ~ 3.0 mol / L). Separation and preconcentration of noble metal ions (Au, Pd, Pt) by QCR have been studied by Inductively Coupled Plasma Atomic Emission Spectronetry (ICP AES). More than 93% of noble metal ions were adsorbed by QCR in 0.1 mol / L HCl; and the analyte could be eluted quantatively by using 2 g / L thiourea -0.1 mol / L HCl as the eluant. The adsorption selectivity to Au, Pd, Pt is good at the existence of some non | noble ions. This method has been applied to the analysis of catalysts and anticancer drugs with satisfactory results. ;