煤矿主扇总负压的测定,以前一直使用“皮托管-U型水计”法。用该法测定时读数困难,且不准确;更不能将总负压变成远传信号输送至矿井调度室,使矿井值班人员随时掌握矿井负压变化情况。为了解决这个问题,重庆煤炭研究所和阳泉矿务局三矿在DBC型美压变送器的基础上改制成功了《KFJ-Ⅰ型矿井主扇总负压检测装置》(简称“检测装置”,下同)。此检测装置在三矿二号井已安装使用了一年多的时间。实践表明它具有使用方便,读数直观,测量精度高,线性、分辨率、稳定性好等优点,完全适合测量矿井主扇负压。
The determination of the total negative pressure of the main fan in coal mines has been using the “Pitot-U-meter” method. It is difficult and inaccurate when measured by this method. Moreover, the total negative pressure can not be transmitted to the remote dispatching room as a remote signal, so mine on-duty staff can keep track of the change of mine negative pressure. In order to solve this problem, the Third Coal Mine of Chongqing Coal Research Institute and Yangquan Mining Bureau restructured “KFJ-Ⅰ main negative total pressure detection device of mine main shaft” (referred to as “detection device”) based on DBC type pressure transmitter. , The same below). This testing device has been installed in the Three Mines for more than a year. Practice shows that it is easy to use, intuitive readings, high accuracy, linearity, resolution, good stability and other advantages, fully suitable for measuring the main fan negative pressure.