论文部分内容阅读
目的:评价微波止血分离器在腹腔镜肝切除术中的应用价值。 方法:回顾性分析2009年7月—2013年6月使用HeSetor微波止血分离器为28例患者行腹腔镜肝切除术的临床资料。 结果:28例均顺利完成,无手术中转、手术死亡发生,手术时间平均(124±45)min,术中出血量平均(140±110)mL。全组患者无术后出血、胆瘘、肝功能衰竭等严重并发症。术后平均住院(6.9±2.7)d。28例患者随访6~53个月,6例肝癌患者术后5~16个月后出现肝内转移复发,切口均未见种植转移。结论:应用微波止血分离器行腹腔镜肝切除术止血可靠,术后无严重并发症,是一种安全可行的切肝方法。“,”Objective:To evaluate the application value of microwave hemostatic device in laparoscopic hepatectomy. Methods:The clinical data of 28 patients undergoing laparoscopic hepatectomy with microwave hemostatic device (HeSetor) from July 2009 to June 2013 were retrospectively analyzed. Results: Laparoscopic hepatectomy was successfully completed in all the 28 patients and no conversion or surgical death occurred. hTe average operative time was (124±45) min and average intraoperative blood loss was (140±110) mL. No postoperative hemorrhage, bile leakage or liver function failure occurred in the entire group of patients. hTe mean length of postoperative hospital stay was (6.9±2.7) d. Follow-up was conducted for 6 to 53 months in the 28 patients, and intrahepatic recurrence occurred in 6 cases with hepatocellular carcinoma in postoperative 5–16 months, but no port site tumor implantation was observed. Conclusion:Laparoscopic hepatectomy with microwave hemostatic device can provide excellent hemostatic effect without severe postoperative complications, so it is a safe and feasible technique for liver resection.