Calculating Methods of Inertia Moment of Turbo-Generator Rotor Using Load Rejection Test

来源 :城市道桥与防洪 | 被引量 : 0次 | 上传用户:slowfast1981
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Calculated results of inertia moment of turbo-generator rotor can be quite different by methods used in load rejection tests. In view of fluctuation features of rotor speed rise curve during load rejection tests, the measurement principle of rotor inertia moment was expounded. Based on the measured data in load rejection tests for an imported type of domestic 300-MW generating unit, the rotor speed rise curve was fitted with three kinds of functions to get initial runup rate, but the obtained results differed a lot from each other. According to analysis on the mechanism of rotor speed rise, m=2 consecutive points averaging or FFT (Fast Fourier Transform) smoothing technology was introduced to process test data, and then the initial runup rate was determined by the method of linear fitting of rotor speed in the range of governing valve closing time. Although the obtained curves had a fluctuating shape, the results of rotor inertia moment for 50% and 100% load rejection tests were of good consistency.
其他文献