采用单吹瞬变法对自行设计的3种CU型一次表面回热器的传热与阻力特性进行了试验研究.建立了数学模型,由数值解求得流体的出口温度与时间及传热单元数NTU间的函数关系.通过配比,获得了换热表面在测定工况下的NTU值.在紧凑式回热器常用的Re=200~800范围内,获得3种CU表面的j因子和f因子的试验关联式.换热面当量直径仅为1.35~1.48 mm,属微小尺度,交错角为52.5°~67.5°.采用综合评价因子j/f对3种表面的性能进行了分析,结果表明1号试件表面具有较佳的性能.经误差分析,所提供的实验关联式的拟合误差不大于16%,具有足够的工程精度.
The single-blink transient method was used to test the heat transfer and resistance characteristics of three self-designed CU-type primary surface recuperators.The mathematical model was established, and the exit temperature and time of the fluid and the number of heat transfer units NTU, the NTU value of the heat transfer surface under the measurement conditions was obtained by the ratio.Under Re = 200 ~ 800, which is commonly used in compact regenerator, the j factor and f Factor correlation test.The equivalent diameter of the heat transfer surface is only 1.35 ~ 1.48 mm, which is a micro-scale, the staggered angle of 52.5 ° ~ 67.5 ° .The performance of the three surfaces were analyzed using a comprehensive evaluation factor j / f, the results show The surface of No. 1 specimen has better performance.According to the error analysis, the experimental correlation provided by the fitting error is less than 16%, with sufficient engineering accuracy.