我省农村机电排灌泵站的启动充水,不论规模大小与台数多少,凡使用卧式水泵的,几乎全采用1~2台水环式真空泵抽气充水。这对节省劳力、减轻机手的劳动强度,成效十分显著。但在使用过程中,由于缺乏必要的技术知识,经常发生如下两种故障:第一、启动真空泵后长时间不能抽气充水,影响主机水泵正常启动。不少机手以为真空泵失灵,要求调换。实际上这是因为进气管道上未装补给水箱所致。必须知道:真空泵在运行中所以能抽气,主要是泵内要保持一定体积的水环,如水环在工作过程中水量损耗、体积减小,就会出现不能正常抽气充水的故障现象。
In our province, the electromechanical irrigation and drainage pump station is filled with water, no matter the size and the number of stations. Where horizontal pumps are used, almost 1 to 2 water ring vacuum pumps are used to pump water. This will save labor and reduce the labor intensity of the driver. The result is very remarkable. However, in the process of using, due to the lack of necessary technical knowledge, the following two kinds of faults often occur: First, starting the vacuum pump for a long time can not be aspirated and filled with water, affecting the normal startup of the host pump. Many drivers think the vacuum pump failure, requiring exchange. In fact, this is because the intake pipe is not filled with water tank. Must know: the vacuum pump in operation so it can be aspirated, mainly in the pump to maintain a certain volume of water ring, such as water ring in the work process of water loss, the volume decreases, there will be a normal pumping can not fill the phenomenon of water.