论文部分内容阅读
Background In response to the increasing concem with the safety of the drug-eluting stent (DES), the present study aimed to evaluate the long-term safety and efficacy of DES used for a Chinese patient population. Methods All patients, who underwent an index elective percutaneous coronary intervention with an implantation of either DES or bare-metal stent (BMS) in a single institution from April 2004 to December 2006, were included in the analysis. A propensity-score matching technique was applied to adjust and to minimize the impact of confounding factors. Results Overall, there were 1465 patients (20.2%) who had undergone an implantation of only BMS, and 5769 patients (79.8%) of only DES. The propensity-score matching technique set up 1321 pairs of patients for analysis. There were no significant differences between the rates of stent thrombosis (definite and probable) of the two groups (1.06% vs 1.21%, P=-0.8580). Although rates of mortality and myocardial infarction (MI) during the 2-year follow-up period had not differed significantly, rates of death/MI (3.0% vs 4.5%, P=0.0263), target-lesion revascularization (TLR, 3.2% vs 8.5, P=0.0001), target-vessel revascularization (TVR, 5.8% vs 9.5%, P