对冷中子源同轴热虹吸管的传热极限做了理论分析 ,推导了同轴热虹吸管传热极限理论计算公式 ,并利用已有的实验数据进行拟合 ,提出了一个简便的计算方法 ,用以进行冷中子源氢热虹吸管的结构设计 ,计算表明 ,当热虹吸管的外管内径为 5 4mm ,内管内径为 2 1mm时 ,传热能力有 3kW。
The theoretical analysis of the heat transfer limit of coaxial thermosyphon with cold neutron source is deduced. The theoretical calculation formula of the heat transfer limit of coaxial thermosyphon is deduced and the existing experimental data are used for fitting. A simple calculation method is proposed, The structure design of hydrogen thermosyphon with cold neutron source is shown. The calculation shows that when the inner diameter of the thermosyphon outer tube is 54 mm and the inner diameter of the inner tube is 21 mm, the heat transfer capacity is 3 kW.