本文详细介绍了放置在100 MeV强流紧凑型回旋加速器主磁铁谷区的实验低温冷板抽气装置的设计,并加工了实验低温冷板性能测试罩,对实验低温冷板内置及外置情况下的抽气参数如抽速、极限压力、抽气容量等参数进行了测试,并对两种不同情况下的测试结果进行了分析比较。结果表明,内置抽速为外置抽速的2.67倍,外置极限真空为内置极限真空的2.75倍,结合100 MeV强流紧凑型回旋加速器的实际情况,100 MeV低温板系统的理论抽速与入口综合流导之比应满足1.1倍工程设计要求。
In this paper, the design of experimental low temperature cold plate suction device placed in the main magnet valley of 100 MeV strong current compact cyclotron is introduced in detail, and the experimental low temperature cold plate performance test mask is fabricated. The experimental low temperature cold plate internal and external conditions Under the pumping parameters such as pumping speed, the ultimate pressure, pumping capacity and other parameters were tested, and two different cases of test results were analyzed and compared. The results show that the built-in pumping speed is 2.67 times of the external pumping speed and the external limiting vacuum is 2.75 times of the built-in ultimate vacuum. Combined with the actual situation of the 100 MeV strong current compact cyclotron, the theoretical pumping speed The ratio of integrated entrance should meet the engineering design requirements 1.1 times.