1.限制水泵几何安装高度从理论上说,在标准大气压下,水泵吸水高度可以达到10.33m。但实际上水泵叶轮进口处不可能绝对真空,加上水泵进水管弯头、底阀、管道内壁水流阻力和泵内水力损失,水泵的吸水高度(即几何安装高度)总是小于10.33m。水泵的几何安装高度越小,进水管路的真空度越小,产生汽蚀的可能性就越小。因此,在安装水泵时,应尽可能降低水泵的几何安装高度。
1. Limit the geometry of the pump installation height In theory, at standard atmospheric pressure, the pump suction height can reach 10.33m. However, in fact, it is impossible to make an absolute vacuum at the inlet of the pump. Coupled with the water inlet elbow, the bottom valve, the water flow resistance in the pipe wall and the hydraulic loss in the pump, the suction height of the water pump (ie the geometric installation height) is always less than 10.33m. The smaller the geometric installation of the pump, the smaller the degree of vacuum in the intake line, the less likely it is to produce cavitation. Therefore, the installation of the pump, pump geometry should be as much as possible to reduce the installation height.