Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for o

来源 :中南大学学报(英文版) | 被引量 : 0次 | 上传用户:twpt168
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Thermal comfort and indoor air quality as well as the energy efficiency have been recognized as essential parts of sustainable building assessment.This work aims to analyze the energy conservation of the heat recovery ventilator and to investigate the effect of the air supply arrangement.Three types of mixing ventilation are chosen for the analysis of coupling ANSYS/FLUENT (a computational fluid dynamics(CFD)program)with TRNSYS(a building energy simulation(BES)software).The adoption of mutual complementary boundary conditions for CFD and BES provides more accurate and complete information of indoor air distribution and thermal performance in buildings.A typical office-space situated in a middle storey is chosen for the analysis.The office-space is equipped with air-conditioners on the ceiling.A heat recovery ventilation system directly supplies fresh air to the office space.Its thermal performance and indoor air distribution predicted by the coupled method are compared under three types of ventilation system.When the supply and return openings for ventilation are arranged on the ceiling,there is no critical difference between the predictions of the coupled method and BES on the energy consumption of HVAC because PID control is adopted for the supply air temperature of the occupied zone.On the other hand,approximately 21% discrepancy for the heat recovery estimation in the maximum between the simulated results of coupled method and BES-only can be obviously found in the floor air supply ventilation case.The discrepancy emphasizes the necessity of coupling CFD with BES when vertical air temperature gradient exists.Our future target is to estimate the optimum design of heat recovery ventilation system to control CO2 concentration by adjusting flow rate of fresh air.
其他文献
Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study.One is the crawlspace warm air heating system and the o
To investigate airflow pattern and its impact on particle deposition,finite-volume based computational fluid dynamics (CFD)simulations were conducted in the dis
A new air distribution pattern,air curtain jet ventilation was presented.The ventilation or airflow patterns and the air velocity produced by air curtain jet we
The fatigue crack growth behavior of an AZ31 magnesium alloy was investigated by comparing the effect of zirconate and phosphate chemical liquids.The morphology
Preparing titanium dioxide from titania-rich slag(TiO2 73wt%)by molten NaOH method has been developed.The effects of temperature and reaction time on the titaniu
Indium doped cadmium sulfide thin films(CdS:In) were produced by the spray pyrolysis technique on glass substrates.AC measurements were used to investigate the
Based on the state-of-the-art studies of solar-soil source heat pump compound system,operation patterns of solar-soil compound system were analyzed,particularly
The globally exponential stability of nonlinear impulsive networked control systems (NINCS) with time delay and packet dropouts is investigated.By applying Lyap
Fluorine doped tin oxide SnO2:F thin films were prepared by the spray pyrolysis(SP) technique on glass substrates by using SnCl2-2H2O as a precursor and NH4F an
Several parameter identification methods of thermal response test were evaluated through numerical and experimental study.A three-dimensional finite-volume nume