Coronal Diffusion-weighted Magnetic Resonance Imaging of the Kidney: Agreement with Axial Diffusion-

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:qidezhong
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background:Coronal diffusion-weighted magnetic resonance imaging (DW-MRI) and apparent diffusion coefficient (ADC) values have gradually become applied (following conventional axial DW-MRI) in the renal analysis.To explore whether data obtained using coronal DW-MRI are comparable with those derived using axial DW-MRI,this preliminary study sought to assess the agreement in renal ADC values between coronal DW-MRI and axial DW-MRI.Methods:Thirty-four healthy volunteers were enrolled in the study; written consents were obtained.All subjects underwent respiratory-triggered axial and coronal DW-MRI using a 1.5-MR system with b values of 0 and 800 s/mm2.The signal-to-noise ratios (SNRs) of the two DW-MRI sequences were measured and statistically compared using the paired t-test.The extent of agreement of ADC values of the upper pole,mid-pole,and lower pole of the kidney; the mean ADC values of the left kidney and right kidney; and the mean ADC values of the bilateral kidneys were evaluated via calculation of intraclass correlation coefficients (ICCs) or Bland-Altman method between the two DW-MRI sequences.Results:The SNR of coronal DW-MR images was statistically inferior to that of axial DW-MR images (P < 0.001).The ICCs of the ADC values of each region of interest,and the mean ADC values of bilateral kidneys,between the two sequences,were greater than 0.5,and the mean ADCs of the bilateral kidneys demonstrated the highest ICC (0.869; 95% confidence interval:0.739-0.935).In addition,94.1% (32/34),94.1% (32/34),and 97.1% (31/34) of the ADC bias was inside the limits of agreement in terms of the mean ADC values of the left kidneys,right kidneys,and bilateral kidneys when coronal and axial DWI-MRI were compared.Conclusions:ADC values derived using coronal DW-MRI exhibited moderate-to-good agreement to those of axial DW-MRI,rendering the former an additional useful DW-MRI method,and causing the ADC values derived using the two types of DW-MRI to be comparable.
其他文献
Background:Benign lymphoepithelial lesion (BLEL) is characterized by symmetric bilateral swelling of the lacrimal and salivary glands and considered a subtype o
GB/T 5226.1-1996rn(代替GB 5226-85)rn本标准等效采用IEC 204-1:1992《工业机械电气设备——第一部分:通用技术条件》(第三版).rn本标准从生效之日起,同时代替GB 5226-85.rn
Background:Subcapital femoral neck fracture in young adults has many complications,and the incidence is increasing year-by-year.The selection of the proper oper
关于如何制定设备评估技术鉴定项目评分标准问题。 在《设备管理与维修》1997年1期和2000年10期分别刊登了笔者的论设备评估技术鉴定有关标准、内容和方法等基本概念和原则,
在《设备管理与维修》2001年第3期“西门子数控系统维修(二)”一文中提到810T系统荧光屏无显示故障的处理方法,由于810T与820T有很多的相似性,笔者在维修过程中曾遇到过与文
我厂是50年代建设起来的化工企业,现有设备大多陈旧落后,长期存在着能源消耗大、劳动强度大、生产效率低、环境污染严重等问题。作为一个老企业,如何在限定的条件下,有计划
Background:In amyotrophic lateral sclerosis (ALS),repeater F waves are increased.Accurate assessment of repeater F waves requires an adequate sample size.Method
在中药制造过程中,我厂过去出渣是靠人力用小推车将废渣堆积起来,积攒到一车后,送往垃圾处理厂.由于生产的不连续性,有时四五天一车,有时则七八天一车,废渣的堆积成为我厂一