【摘 要】
:
The main objective of this study was to evaluate eight kinds of trace element pollutants in groundwater from a typical coal mine area,and carry out a corresponding health risk assessment for the local populace.To do this,34 shallow groundwater (SG) sample
【机 构】
:
Engineering Research Center of Coal Mine Exploration of Anhui Province (Suzhou University,Suzhou 234
论文部分内容阅读
The main objective of this study was to evaluate eight kinds of trace element pollutants in groundwater from a typical coal mine area,and carry out a corresponding health risk assessment for the local populace.To do this,34 shallow groundwater (SG) samples and 18 mid-layer groundwater (MG) samples were collected from the Sulin mining area.To minimize the uncertainties in the health risk assessment,this paper relied on Monte Carlo simulations and sensitivity analysis.The results revealed that Sr and Mn contents exceeded their corresponding WHO (Guidelines for drinking water quality,4th edn.Geneva,2011) guidelines and Chinese groundwater standards (GB/T14848-2017),while the other analyzed trace elements remain below those threshold values.The calculated hazard quotient and hazard index values for adults from ingestion exposure to SG and MG were well below the threshold limit of 1.Probabilistic simulations further show that the total cancer risk value above the limit of 1 × 10-6 is 0% for SG and 29.39% for MG.Sensitivity analysis identified the Sr and Cr contents as the most relevant element variables affecting the probabilistic non-carcinogenic and carcinogenic risk values in the model,respectively.
其他文献
At present,non-pillar entry protection in longwall mining is mainly achieved through either the gob-side entry retaining (GER) procedure or the gob-side entry driving (GED) procedure.The GER procedure leads to difficulties in maintaining the roadway in mi
Melina wood torrefied at 260 ℃ for 60 min was agglomerated with lean grade coal fines into composite briquettes using pitch as binder.Torrefied biomass (3%-20%) and coal fines (80%-97%) were blended together to produce the composite briquettes under a hyd
Four coal samples from Jharia basin,India are treated with nitric acid in glacial acetic acid and aqueous media to find out the chemical,petrographic and spatial structure of the organic mass by X-ray diffraction (XRD) and Fourier Transform Infrared Spect
Aiming at the poor location accuracy caused by the harsh and complex underground environment,long strip roadway,limited wireless transmission and sparse anchor nodes,an underground location algorithm based on random forest and compensation for environment
Tri-flo cyclone,as a dense-medium separation device,is one of the most typical environmentally friendly industrial techniques in the coal washery plants.Surprisingly,no detailed investigation has been conducted to explore the effectiveness of tri-flo cycl
An accurate assessment of root respiration in mine reclaimed soil is important for effectively evaluating mining area ecosystems.This study investigated dynamic changes in root respiration and the contribution of root respiration to total soil respiration
Crude phenols extracted using organic solvent from the wastewater of a typical fixed-bed gasification process was used as a raw material,and the distillation range was analyzed.The wide and narrow fractions of the raw material derived from distillation ra
A tool for calculating the economic and environmental impacts of the use of byproducts of industrial processes that can substitute for perishable resources was presented.This was exemplified by fly ash (the fine fraction of ash originating from coal burne
A 72-h ex situ hard coal gasification test in one large block of coal was carried out.The gasifying agent was oxygen with a constant flow rate of 4.5 m3/h.The surroundings of coal were simulated with wet sand with 11% moisture content.A 2-cm interlayer of
The movement of the floating connecting mechanism between a hydraulic support and scraper conveyor is space movement;thus,when the hydraulic support pushes the scraper conveyor,there is an error between the actual distance of the scraper conveyor and the