【摘 要】
:
This study explores the essential issues pertaining to a landscape bridge based on a multi-scale methodology,in view of the paucity of design theories for contemporary landscape bridges.We contribute to reinterpret landscape bridges on their physical temp
【机 构】
:
Department of Architecture,Southeast University,Nanjing,China;Department of Civil,Building and Envir
论文部分内容阅读
This study explores the essential issues pertaining to a landscape bridge based on a multi-scale methodology,in view of the paucity of design theories for contemporary landscape bridges.We contribute to reinterpret landscape bridges on their physical temporal-spatial scales,instead of from perspectives of individual disciplines or their mechanical cooperation.Envisaged in a new systematized framework,we elaborate the dominant and their opposite counterparts of landscape bridges from a binary deconstruction point of view,i.e.,(1) Devel-opment and retrogression on the temporal scale,(2) connection and separation on the spatial topographic scale,(3) skyphilia and topophilia on the spatial landscape scale,and (4) extrover-sion and introversion on the spatial architectural scale.The deconstructed multifaceted scales are instrumental in understanding landscape bridges from various perspectives,with a pyramid model proposed afterward to mediate the discovered oppositions and stimulate the cross-scale interactions.Various possible design paths could be derived from this well-organized and open-minded multiple system,which is initially expected in this study to inspire bridge designers with dissimilar backgrounds and calls for a wider ramification.
其他文献
在建设模仿家庭室内长期落灰场景的尘埃室的过程中,使用管道进行微量灰尘的输送是一个技术难点,原因是采用固体料粉气力微量输送的装置容易被堵塞.三通管接头气固喷射器是采用三通管接头改造而得,该装置依赖空气输送微量灰料进入尘埃室,同时满足长时间运行不积灰堵塞的要求.对同一尺寸的三通管接头改造结构尺寸,并进行了尺寸优化实验分析,分析比较了不同比例截面积的引射管风量、 负压(真空度)、 引射比.对实验结果进行分析,得出优化尺寸结果,即喷射口截面积与三通管截面积之比率为0.14~0.17(约为0.15左右).这个优化结
典型电站的通气洞主要与电站尾水闸门的开闸排水工艺有关,当电站机组运行尾水闸打开时,大量的尾水会涌入尾水调压室,导致调压室内的空气通过通气洞被极速排出.为了准确得到尾水进入调压室后,通气洞内的空气流动状态,以及其与通风兼安全洞连接处的压力波动情况,本文根据设计工况下调压室内的实际水流量进行理论分析计算,并以该分析结果为依据,对尾水闸打开时主厂房通风的情况进行了准确分析.
B IPV控制中心把空冷型PV/T构件整合到建筑外墙中,实现了太阳能光电光热一体化高效综合利用.设置排风机与南墙东侧的PV/T构件相结合,夏季和过渡季进、 排风电动百叶开启自然散热.冬季开启排风机,热空气送至地板下的蓄热混凝土进行蓄热,实现光伏余热直接热利用.本文对此系统进行了实验测试,蓄热混凝土系统平均温升5.8℃,蓄热效果良好,具有推广应用价值.
本文首先对国内建筑设备监控系统标准建设情况及其在医院建筑的应用现状进行了调查分析,在此基础上提出了一种建筑设备智能管控系统,最后将该系统应用在了福建省某三甲医院,结果表明新系统既可大幅提升医院建筑设备能效水平和综合能源利用效率,降低建筑设备运行和维护的各项成本,也可提升医院建筑设备安全管理水平,将以往的事后维护向事前维护与预测性维护转变,大幅降低建筑设备安全风险.
Given the cultural and environmental potential presented by historical water infra-structures in urban contexts,this article states the evidence of a not much documented urban phenomenon in Portugal,the refurbishment of water heritage protected areas moti
经调研发现,不同送排风风口位置、 独立送排风或交叉送排风,有无连通洞3种因素,对地下封闭调蓄池通风效果的影响目前尚不明确,气流组织形式有优化空间.本文从通风有效性和排污有效性2个角度出发,构建调蓄池通风气流分布评价指标,基于广西某调蓄池项目,以H 2 S为示踪气体,进行CFD模拟.结论:高送低排的通风有效性和排污有效性最高.交叉送排风的气流分布效果不如独立送排风.增设连通洞后,调蓄池内H 2 S平均浓度和空气龄可分别降低35.56%,8.26%,排污效率提高2.79,通风有效性和排污有效性均大幅改善.
通过对比补气增焓及采用电子膨胀阀控制排气过热度的低环温空气源热泵应用在室外环境温度-15℃ 以上的性能对比以及在-15℃下运行的经济性分析,确定了电子膨胀阀控制排气过热度低环温空气源热泵机组的辅助电加热使用时间节点,为设计选型、 工程应用提供参考.
模拟一个集成了不同采暖系统的办公室,以此来评估和预测不同采暖系统建筑物的热舒适性及能耗.采用CFD软件对地板辐射采暖,常规散热器采暖以及是否辅助机械通风等六个情况进行建模与分析,结果表明在辐射采暖系统下室内的热舒适性以及温度控制都要优于传统的采暖系统,适当的机械通风可以辅助改善室内的热舒适性.
介绍了燃气压缩式及吸收式空气源热泵的工作原理,从理论上进行冬季制热过程的经济性分析.研究结果表明:压缩式热泵制热性能优于吸收式热泵.燃气压缩式热泵一次能源利用率优于燃气吸收式热泵、 电驱动压缩式热泵.燃气压缩式热泵更为经济.
为应对新型冠状病毒等呼吸道传染性疾病的筛查防治工作,对新建、 改扩建的发热门诊及留观病房的通风、 空调系统提出设计原则及控制要点,总结出有效控制三区域二走道的压力梯度、 定向气流流向是避免新冠病毒传染的设计手段,并强调室内外通风系统取风、 排风口位置的布置原则,使建筑物对周围环境影响降到最低.