装载机变速油压低的原因

来源 :工程机械与维修 | 被引量 : 0次 | 上传用户:tanxiaoxi
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
一台ZL50C型装载机,修后变速器的变速油压只有0.7 MPa,与规定值(1.1~1.5MPa)相差太远。 该机在修理前,变速油压比较正常,3个挡位的压力均为1.3 MPa,而且还比较稳定。这次维修的主要原因是,机械动力严重不足。在拆检的过程中,发现超越离合器严重失效。原因找到以后,就没有再对变矩器进行分解。为了确保修复后机器的动力得到保证,还将原来已经使用了10个月的变速泵进行了更新。在装配前,除更新了所 A ZL50C-type loader, modified gearbox transmission oil pressure is only 0.7 MPa, and the specified value (1.1 ~ 1.5MPa) is too far away. Before the machine was repaired, the transmission oil pressure was normal, and the pressures in the three gears were both 1.3 MPa, which were still relatively stable. The main reason for this maintenance is a serious lack of mechanical power. In the process of dismantling, it was found that the overrunning clutch seriously failed. When the reason is found, there is no further decomposition of the torque converter. In order to ensure that the power of the repaired machine is guaranteed, the variable speed pump that has been used for 10 months has also been updated. Before the assembly, in addition to the updated
其他文献
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
加热炉是石油化工行业最常用的设备之一,也是消耗能量最多的设备.它是利用燃料在炉膛内燃烧产生高温火焰与烟气作为热源,通过热量传导、辐射传热和对流传热来加热炉管中流动
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
我单位的两台石川岛产的CCH250WE型轮胎起重机已使用了10年,其典型故障如下。1.发动机曲轴箱通气管向下滴水 某次冬检时发现,发动机曲轴箱通气管向下滴水。停机检查后知:散
故障现象 一台加藤NK400E—Ⅲ型汽车起重机,在使用时起重臂变幅缸和伸缩缸的动作均无力,速度缓慢;测得为其供油的2~#泵(见图1)压力仅为8.5 MPa(标准值为IOMPa)。1~#泵为起升
目前,CB-B型齿轮泵在自卸汽车与工程机械操纵机构中运用较多,现将其常见故障及排除方法介绍如下,供参考。1.产生振动与噪声的原因与排除 (1)吸入空气 ①CB-B型齿轮泵的泵体
一台YZ20JC型振动压路机,在工作中经常出现侧传动驱动齿轮被打坏的现象,致使机器的行走方向突然跑偏,并伴有清脆的敲击声。紧急停机检查时发现,驱动齿轮轴压盖破裂引起轴位
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥