1、在罐区、油泵棚、汽车装车台等爆炸危险场所,若配电装置、电气设备等不符合防爆要求,电器设施开启或闭合时能产生电弧及电气火花。2、油罐、码头及输油管的防雷装置缺失、设施损坏、保护范围不够、或接地电阻超标,雷雨季节直接雷、感应雷及雷电波侵入引起火花。3、油库内配电系统电线老化、短路,设备故障等产生火花。4、油品输送、灌装、接卸时由于摩擦产生大量的
1, in the tanker area, oil pump sheds, car loading stations and other dangerous places of explosion, if the power distribution equipment, electrical equipment does not meet the explosion-proof requirements, electrical facilities open or closed to produce arc and electrical sparks. 2, Tanks, wharves and pipelines lightning protection device is missing, damage to facilities, protection is not enough, or grounding resistance is excessive, the thunderstorm season direct thunder, lightning and lightning induced lightning intrusion caused sparks. 3, distribution system in the oil depot aging, short circuit, equipment failure and other sparks. 4, oil transportation, filling, loading and unloading due to a large number of friction