Unbalance Force Compensation in Active Magnetic Bearing Rotor system Using the Adaptive Open-loop Ob

来源 :2016冷冻空调亚洲大会(8th Asian Conference on Refrigeration and Air-c | 被引量 : 0次 | 上传用户:loyovue0603
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  The control of the Active Magnetic Bearing(AMB)rotor is a crucial point of the AMB centrifugal compressor for the air-conditioning equipment,in which the main disturbance of AMB rotor in high-speed operation is the unbalance force,it is caused by that there are always be a small radial offset between the rotor center of mass and the axis of rotation of the shaft,the radial offset generates radial disturbance force to the square of the rotating speed.
其他文献
Taiwan computer appliances and audiovisual electronic manufacturing industries use 43.9 billion kWh of electricity,which takes up 17.5%of all the electricity usage in Taiwan.This shows that it has a b
会议
This study demonstrates the experimental heat transfer coefficient and computational fluid dynamic(CFD)simulation of two-phase flow boiling of R32 in small tube.The experimental data were conducted in
会议
This work presents an experimental investigation of a desiccant device integrated with heat pipe heat exchanger.Drying rate of the conventional hot air dryer is significantly affected by the differenc
会议
This paper describes the experimental results and the performance of ground source heat pump using the direct expansion method.The underground temperatures are more stable than air temperature.The tem
会议
Healthy sensors are essential for normal and optimal operation of HVAC&R systems.Various data-based methods are employed widely for sensor fault detection,diagnosis and error data reconstruction nowad
会议
The electric vehicles are an automobile propelled by electric power and has the advantage of zero emission on the road.With its energy-saving,low pollution,and efficient mobility benefits,the electric
会议
This paper aims to develop a wind variability control system by using(Received signal strength indicator)RSSI information.We make field measurement of the path loss in the Bluetooth wireless transmiss
会议
The GSHP that use a direct expansion method is expected to have higher performance of energy-saving than the conventional type of the GSHP.We evaluated the quantity of heat by measuring temperature,hu
会议
According to the groundwater hydraulic problem of a water source heat pump air conditioning system design of a hospital in Wuhan,hydraulic calculation was flexible and diverse in actual projects,not n
In many cases,heat pump systems fail to supply cool air due to refrigerant leakage.It is very important to estimate the refrigerant charge amount(or leak amount)of the heat pump with limited number of
会议