【摘 要】
:
Current asthma treatments are effective for most but not all patients.Asthma is classified as a complex genetic disease with its pathogenesis and expression (severity) determined by the interaction of
【机 构】
:
Professor of Medicine Wake Forest School of Medicine Medical Center Boulevard Winston-Salem,NC 27157
【出 处】
:
第六届北京协和呼吸病学峰会暨第二届ACCP呼吸与危重症最新进展临床峰会
论文部分内容阅读
Current asthma treatments are effective for most but not all patients.Asthma is classified as a complex genetic disease with its pathogenesis and expression (severity) determined by the interaction of many genes and environ mental factors.Asthma is characterized by its heterogeneity in terms of its clinical and inflammatory phenotypes and their responses to therapy.This disease heterogeneity likely has played a role in variable results from clinical trials that evaluate specific inhibitors of inflammatory mediators ( biologics) in asthma.Moreover,although existing treatments are effective and safe in most asthma patients they may be less effective or potentially harmful in others.In addition,if an individual with asthma is less responsive to standard therapies such as corticosteroids because of specific pharmacogenetic interactions then that patient with asthma will be classified as having more severe or diffi cult-to-treat asthma.Pharmacogenetic approaches hold the promise of matching individualized treatments to spe cific genotypes in a way that minimizes side effects while improving therapeutic outcomes.
其他文献
Focal spot size is an important factor that affects the spatial resolution and the projection image unsharpness.More seriously,the size and position of the focal spot may change as time goes or when t
目的 研究3D影像对观看者的影响,探讨脑电信号的功率谱特征与观看者不适感之间的联系,寻找用脑电信号的特征评价3D影像导致不适感的客观指标.方法 分别在3D和2D两种实验条件下,对实验前静息和实验过程中的脑电信号进行功率谱密度分析,采用统计分析方法进行假设检验并对照分析.
[PURPOSE] To evaluate the accuracy (-)f the geometric calibration method for projection matrix computation and geometric parameter extraction,a cone-beam CT with a fiat-panel detector was simulated.MA
Objective To present the methods of medical image quality assessment and optimization.Methods Based on human vision characteristics,the image vision quality parameters were analyzed in order to find t
呼吸运动引起较大幅度的胸腹部器官运动,造成传统CT图像上的运动伪影,影响放疗精确度及效率。四维CT(four-dimensional computed tomography,4DCT)技术能够提供反映内部器官运动的四维图像,有助于提高放疗精确度。传统4DCT技术在低剂量时将产生图像噪声及伪迹,且依赖于外部呼吸监测系统,无法在常规CT机上实现,使得设备昂贵。针对上述问题,本文提出基于图像最小边界不连
Background and objective Recent studies showed a controversy about whether DARTEL had significant improvement over standard registration in VBM analysis.In the current study,the primary objective was
Objective The aim of this paper is to study the methods of the 3D interactive clinging of MRI image in arbitrary orientation based on VTK.Materials or Methods The Visualization Toolkit (VTK) is an ope
Objective The aim of this paper is to study a simple method of projection coefficient calculation for image reconstruction based on the PET Simulation by GATE.Materials or Methods GATE (Geant4 Applica
本文介绍骨髓移植术后3年出现第二肿瘤1例,患者,女,39岁,因“反复发热、咳嗽、咳痰3月,胸闷、喘憋1周”就诊。骨髓移植是器官移植的一种,通过将正常骨髓由静脉输人患者体内,以取代病变骨髓的治疗方法,根据干细胞来源不同分为自体干细胞移植和异体干细胞移植,第二肿瘤是骨髓移植后常见的远期并发症。尽管国外学者对骨髓移植后第二肿瘤的发生有了比较深人的研究,但目前国内期刊尚未检索到此类病人的报道,在结合本病例
Milwaukee,Wisconsin Milwaukee,Wisconsin ACCP Overview Worlds largest clinical pulmonary,critical care,and sleep medicine society (more than 18,000 members in 100 countries) founded in 1935 Members inc