Complementary Processing for an Image with higher Luminance

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:xiaosun988
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose: To propose a method for adaptively optimizing an image quality with over luminance in order to realize the optimization of visual quality of over luminance image.Methods:At first it is demonstrated that the complementary image of higher luminance image which mean luminance is bigger than 127.5 is a lower luminance image.And then a proven method for optimizing lower luminance image is used to adaptively optimize the complementary image of the higher image.Thirdly,finding the inverse image of the optimized complementary image is found to acquire a optimized image of the higher image.Finally,an equation system for directly and adaptively optimizing higher luminance image is derived mathematically.Results:An equation system for directly and adaptively optimizing higher luminance image,called Zadeh-X transformation,is obtained as follows.(1)subject to(2)(3)where ML is the mean luminance.and represent the gray/chroma value of pixel at point(x,y)in the original image and object image before and after transformation.Here let k=255.The Beta,Delta and k called the transformation parameters.The directly and adaptively optimizing higher luminance image is completed after coding equations from(1)to(3).The method achieves a superior outcomes by means of an assessment called image quality assessment function.Conclusions:The theoretical equation system for directly and adaptively optimizing higher luminance image is established.The experimental results demonstrate that the performance of this equation system is superior and the resulting images meet the criteria of no increasing information entropy.
其他文献
  Nuclear magnetic resonance(NMR)image is often used in medical diagnosis.Andimage super-resolution(SR)is the important steps in the NMR image analysis,which
会议
  Purpose: X-ray scatter poses a significant limitation to image quality in cone-beam CT(CBCT),as well as beam hardening,resulting in image artifacts,contrast
会议
  Automatic lung tumor localization plays a significant supporting role on diagnosing and treatment of lung cancer.It could be able to avoid clinicians making
会议
  Purpose: To improve the image reconstruction quality of multi-energy photon counting X-CT based on prior image constrained compressed sensing by evaluation
会议
  Purpose: Segmental scanning protocol of Multi-energy computed tomography(MECT)is an easy-to-implement and no-extra dose induced way realized in conventiaona
会议
  Objective:Evaluated the speed and accuracy of GPU-based collapsed cone dose calculation.Methods:Ten Head and Neck patients and Ten cervical carcinoma patien
会议
会议
  Objective:To investigate the treatment plan quality between two treatment planning systems(TPS)for volumetric modulated Arc therapy(VMAT).Materials and Meth
会议
  Purpose: The application of limited-angle computed tomography(CT)has great expectation in some clinical circumstance such as dental CT imaging.Existing iter
会议
  Purpose:Head motion in PET/CT leads to artifacts due to the mismatch of PET and CT images.This work aims at reducing motion artifacts in PET image reconstru
会议