Clinical application of localizing the mitral valve prolapse by real-time 3-dimensional transesophag

来源 :第八届北京五洲国际心血管病会议 | 被引量 : 0次 | 上传用户:initialD2004
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective The aims of this study were to analyze the features of mitral valve (MV) prolapse on the real-time 3-dimensional transesophageal echocardiography (RT-3D-TEE) and to explore the value of RT-3D-TEE for localizing the mitral valve prolapse.Methods Twenty-three patients undergoing MV repair or MV replacement for mitral regurgitation (MR) were studied prospectively.Intraoperative RT-3D-TEE examinations wereperformed.The features and locations of MV prolapse on the RT-3D-TEEwere analyzed and compared with the anatomic findings reported by the cardiac surgeons.The surgical view from the left atrium was used when analyzing the RT-3D-TEE features of MV prolapse.Results The surgical view from the left atrium were clearly demonstrated in all of the 23 patients and 138 segments were studied.Preoperative 33 segments of MV prolapse were diagnosed and 105 segments were normal.Of the MV prolapse, the chordal ruptures were found in 16 patients and the vegetations were found in 3 patients.The sensitivity, specificity, positive predictive value, negative predictive value and the overall accuracy of localizing the MV prolapse for the RT-3D-TEE were 91.4%, 99%, 97.0%, 97.1% and 97.1%respectively.Additionally, the overall accuracy of identifying the ruptured chordae tendineae and vegetations was respectively 99.3% and 100%.Conclusions RT-3D-TEE is an effective imaging tool for diagnosing MV prolapse and can provide some additional and helpful information.
其他文献
会议
会议
会议
目的 综述肺静脉闭塞病的诊治进展材料与方法 以肺静脉闭塞病及肺动脉高压为自由词,搜索近3年国内外文献进行综述.结果 1.肺静脉闭塞病是一种罕见病,多数病因不明,迄今国外报道不足200例,国内不足10例.2.肺静脉闭塞病临床表现无特异性,活动性呼吸困难进行性加重是其主要表现,其它尚有咳嗽、咯血、胸痛、乏力、嗜睡、晕厥、猝死等,晚期可出现右心衰竭的症状和体征.3.胸部高分辨CT主要特征是小叶中心型毛玻
会议
Objective To analyze the clinical characteristics of ventilator-associated pneumonia (VAP) in patients admitted by emergency intensive care unit (EICU), pathogen distribution and drug resistance chara
Objectives To establish normative reference ranges of fetal cardiac hemodynamic between 20 and 34 per weeks including: velocity of mitral valve and tricuspid valve, artery valve, important physiologic
Objective To discuss the effect on spinal cord blood supply after simultaneous thoracic and abdominal endovascular aortic repair for lesions involving both descending and abdominal aorta.Methods A ret
Objective To evaluate mitral annulus dynamic morphology over the cardiac cycle in patients with mitral valve prolapse(MVP) by using real-time three-dimensional transesophageal echocardiography (RT-3D-
Objective To evaluate mitral annulus geometry and function in the patients with mitral valve plasty by using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE).Methods RT-3D-TEE
Objective To assess the clinical meaning ofEchogenic intracardiac focus in Fetuses by echocardiography.Methods The data of 310 fetuses diagnosed as Echogenic intracardiac focus by echocardiography wer