二维剪切波弹性成像的技术模式在诊断乳腺癌方面的应用:质量与大小关系的探究

来源 :第三届全国暨国际超声分子影像及生物效应和治疗学术会议 | 被引量 : 0次 | 上传用户:xgimi1985
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Objective To explore the diagnostic value of shear wave quality(SWQ) for two-dimensional shear wave elastography (2D-SWE) in the diagnosis of breast lesions with different sizes.Methods This prospective study was approved by the institution review board and informed consent was obtained from all the patients.From August 2014 to January 2015,243 patients with 260 pathologically proven breast lesions were included into this study.All patients underwent conventional ultrasound(US) and 2D-SWE examinations.According to the size, all breast lesions were divided into three groups (group one: ≤ 10mm,group two: 10 ~ 20mm,group three: ≥20mm) and then make an agreement.The evaluation of SWQ for 2D-SWE was as follow:if the SWQ images of breast lesions were in the whole green, the SWQs were regarded as good.On the contrary, if the images had yellow or/and red component, the SWQs were regarded as poor.The evaluation of SWQ were performed by two independent observers with difference experience of breast ultrasound diagnosis (one with 2-year experience and the other with 7-year experience).Lastly, in the three groups with different sizes,the comparisons of poor SWQ rates between benign and malignant breast lesions were performed (P< 0.05), respectively.And the Observer consistency was evaluated.Results In this study,63 (95.4%) breast lesions were confirmed by postoperative pathology and 8 (4.6%) breast lesions were proven by cytopathology.Pathologically, 192 (73.8%) breast lesions were confirmed as benign and 68 (26.2%) ones were confirmed as malignant.For all the breast lesions,the poor SWQ rate is 25.4% (66/260) with 38 (19.8%) in the benign breast lesions and 28 (41.2%) in malignant ones.For the benign breast lesions, the rates of poor SWQ were 6.3% (4/63), 21.4% (21/98) and 41.9% (13/31) for the group one, the group two and the group three, respectively.For the malignant breast lesions, the rates of poor SWQ were 10.0%(1/10),34.5%(10/29) and 58.6%(17/29) for the group one,the group two and the group three,respectively.There was significant difference of the poor SWQ rates between benign and malignant breast lesions for the group one and group two (Both P< 0.05),whereas there was no significant difference for group three (P=0.20).The Kappa value between the two observers for SWQ assessment was 0.837.Conclusion It is more suitable to use the SWQ from 2D-SWE for breast lesions with sizes less than or equal to 20 mm than for ones with sizes more than 20 mm in the diagnosis of breast carcinoma.
其他文献
  在高功率光纤激光焊接中,金属蒸汽羽烟对焊缝熔深的影响在低压情况下会显著地加强。本文在不同的低气压下,用功率为8kW,速度为1m/min进行了一系列激光焊接实验。利用高速
会议
  Based on the fact that cold spraying (CS) is increasingly attracting more and more attention from the researchers and industries worldwide, it is useful to
会议
  Copper thin films were deposited on inner wall of rectangular carbon fibre reinforced plastic(CFRP) waveguide with high aspect ratio by plasma enhanced atom
会议
  Objective To investigate the transfection efficiency of combining ultrasound targeted microbubble destruction (UTMD) and classic nuclear localization signal
会议