The dosimetric research of target regions and bone in three and two-dimensional brachytherapy techni

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:xingke198621
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  purpose To compare the dosage of target regions and bone in three-dimensional(3D)brachytherapy and two-dimensional(2D)Paris system brachytherapy for soft tissue sarcomas.Methods The brachytherapy was performed in total 18 soft tissue sarcomas patients who received the surgery with catheter insertion.The plans of 3D brachytherapy and 2D Paris system brachytherapy was designed in every patient respectively.The dosages differences of target regions and bone in patients and the distance between them were analysised between the two brachytherapy plans.Results There was no significant difference of target regions CTV-D100 between two brachytherapy techniques.The target regions CTV-D90 in 3D brachytherapy was much higher than 2D Paris system brachytherapy(P<0.05).The max dose D2cc in bone between two brachytherapy techniques are almost the same when the distance between the CTV and bone are farther(>8mm);but when they are near,max dose D2cc of the 3D brachytherapy is significant lower than 2D in bone.Only 38.9%plans of 2D Paris system brachytherapy and all 3D brachytherapy but one could achieved the requirement of clinical prescription dose of 400cGy*10 for CTVD90 and D2cc<5%for bone.The catheter insertion of that one is not good.Conclusions The 3D brachytherapy for soft tissue sarcomas could optimize the target coverage and reduce the dosages of bone(when distance>8mm)compared with 2D Paris system brachytherapy.The dosages of target regions and bone in both two brachytherapy techniques are maybe affect by the Catheter insertion,so the research should be undergo.
其他文献
Purpose:Abdominal compression is known to be effective but,often makes external-marker-based monitoring of breathing motion not feasible.In this study,we developed and evaluated a system that enables
会议
Purpose:To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans.Methods:For prostate SBRT cases,rectal wall is identified as organs at risk and
The purpose of this study was to conduct quality assurance(QA)of plans of four patients having multiple metastatic lesions(targets)simultaneously treated with mono isocentric three dimensional conform
Purpose:This study aimed to determine the optimal fractions scheme(FS)in small peripheral non-small cell lung cancer(NSCLC)patients undergoing stereotactic body radiotherapy(SBRT)by comparing the ther
Purpose To explore the real-time dose verification method in volumetric modulated arc radiotherapy(VMAT)with a 2D array ion chamber array.Methods The 2D ion chamber array was fixed on the panel of ele
Purpose:The most common type of cancer among women is breast cancer.Accurate assessment of skin dose in radiotherapy can provide useful information for clinical consideration.The aim of this study is
Purpose:A novel breathing guidance method by combining the personalized audio-visual biofeedback(BFB)system,the breath hold(BH)method,and the synchrotron-based gating technique was developed to help p
Purpose:X-ray scatter photons result in significant degradation of cone-beam CT(CBCT)image quality.Measurement based algorithms using beam block directly acquire the scatter samples and achieve signif
Purpose:Radiochromic EBT3 film is a later generation of radiochromic films.The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods:A RANDO p
Purpose:To quantify the advantages in prescription dose escalation from helical tomotherapy(HT)compared to LINAC-based IMRT on nasopharynx cancer.Material and methods:20 patients with nasopharynx canc