Neural network-based computer-aided diagnosis in distinguishing malignant from benign solitary pulmo

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:ping996115122xing
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Computer-aided diagnosis (CAD) of lung cancer is the subject of many current researches. Statistical methods and artificial neural networks have been applied to more quantitatively characterize solitary pulmonary nodules (SPNs). In this study, we developed a CAD scheme based on an artificial neural network to distinguish malignant from benign SPNs on thin-section computed tomography (CT) images, and investigated how the CAD scheme can help radiologists with different levels of experience make diagnostic decisions.Methods Two hundred thin-section CT images of SPNs with proven diagnoses (135 small peripheral lung cancers and 65 benign nodules) were analyzed. Three clinical features and nine CT signs of each case were studied by radiologists,and the indices of qualitative diagnosis were quantified. One hundred and forty nodules were selected randomly to form training samples, on which the neural network model was built. The remaining 60 nodules, forming test samples, were presented to 9 radiologists with 3-20 years of clinical experience, accompanied by standard reference images. The radiologists were asked to determine whether a nodule was malignant or benign first without and then with CAD output.Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis.Results CAD outputs on test samples had higher agreement with pathological diagnoses (Kappa=0.841, P<0.001).Compared with diagnostic results without CAD output, the average area under the ROC curve with CAD output was 0.96(P<0.001) for junior radiologists, 0.94 (P=0.014) for secondary radiologists and 0.96 (P=0.221) for senior radiologists,respectively. The differences in diagnostic performance with CAD output among the three levels of radiologists were not statistically significant (P=0.584, 0.920 and 0.707, respectively).Conclusions This CAD scheme based on an artificial neural network could improve diagnostic performance and assist radiologists in distinguishing malignant from benign SPNs on thin-section CT images.
其他文献
A selenium-modified hyaluronic acid(HA) compound(SeHA) was synthesized as a mimic of glutathione peroxidase(GPX). IR and NMR spectra of SeHA predict that the -C
Glomus tumors, also known as glomangiomas, are rare and originate in the neuromyoarterial glomus, a normal arteriovenous shunt which is abundantly supplied with
Objective: To investigate the clinicopathological risk factors for fatal recurrence of hepatocellular carcinoma (HCC) in orthotopic liver transplant recipients
In the past, living donor nephrectomy required an open flank incision that results in postoperative morbidity and a prolonged hospital stay. Since its introduct
AIM: To investigate the expression of Cyclooxygenase-2(COX-2), proliferating cell nuclear antigen (PCNA), Ki-67and p53 in gastrointestinal stromal tumors (GISTs
AIM: To study mutations in the P-type ATPase (ATP7B)gene responsible for Wilson disease (WD) in the Eastern Chinese population, and the possible correlation of
Background Recent studies showed that aminoglycosides destroyed the cochlear cells and induced ototoxicity by producing reactive oxygen species, including free
Solitary luteinized follicle cyst, a rare cause of ovarian enlargement during pregnancy and puerperium, is a self-limited disease that can regress spontaneously
AIM: To identify risk factors related to pancreatic fistula in patients undergoing distal pancreatectomy (DP) and to determine the effectiveness of using a stap
目的调查深圳市大鹏新区育龄妇女宫颈健康状况。方法筛查3986例,全部做HPV、TCT检测,高危人群均做阴道镜,并镜下行宫颈多点活检。结果 HPV、TCT阳性率16.39%,其中HPV阳性12.6