论文部分内容阅读
目的:建立测定西替利嗪尿药浓度的反相离子对高效液相色谱法(RP-HPLC)。方法:以Nova-pakC18、4μm色谱柱为分离柱,流动相为乙腈∶磷酸盐缓冲液(0.02mol·L-1、NaH2PO4)∶三乙胺(50∶50∶0.15,V/V),pH值3.07,内含十二烷基硫酸钠(SDS)0.0105mol·L-1,去氯羟嗪为内标,UV检测波长229nm。结果:方法线性范围为0.2~20μg·ml-1(r=0.9999),平均回收率为96.4%±2.3%,日内和日间精密度均小于5%。结论:采用RP-HPLC法测定盐酸西替利嗪片的正常人尿药浓度,简便,迅速,准确
Objective: To establish a reversed-phase ion-pair high performance liquid chromatography (RP-HPLC) for the determination of urinary drug concentration of cetirizine. Methods: Nova-pakC18 column was used as the separation column. The mobile phase consisted of acetonitrile: phosphate buffer (0.02mol·L-1, NaH2PO4): triethylamine (50:50:0.15, V / V ), PH 3.07, containing sodium dodecyl sulfate (SDS) 0.0105mol·L-1, dechlorination as internal standard, UV detection wavelength of 229nm. Results: The linear range of the method was 0.2 ~ 20μg · ml-1 (r = 0.9999). The average recovery was 96.4% ± 2.3%. The intra- and inter-day precision was less than 5%. Conclusion: The determination of urinary drug concentration of cetirizine hydrochloride tablets by RP-HPLC is simple, rapid and accurate