论文部分内容阅读
Layup temperature is a vital factor that affects the production quality of automated fiber placement for thermoset composites.For high quality production,this paper proposes a new pre-diction model of layup temperature by considering the structure of infrared heater of automatic fiber placement equipment.The model was first verified by comparing with the temperature results of layup experiments.Then a prediction on the effects of heater structure arrangement on layup temperature was conducted in the model.The research shows that the length of infrared tube and the radian of reflective-film have significant influences,rather than other parameters.According to this investigation,a heater structure-based heating strategy was presented in the paper to effi-ciently achieve constant temperature control in variable speed layup process.