论文部分内容阅读
【摘 要】随着现代化城市建设的飞速发展,人们在满足生活空间基本功能不仅要有标新立异的外观,更要有完善的内部设施,在舒适性的前提下对建筑工程及其附属设施的质量要求也逐渐变高。同时对采暖系统、给排水系统、空调通风系统也提出了更高的要求。一座温馨的建筑不仅需要各个专业设计人员精心设计,做好本职工作,而且更有赖于他们之间的密切配合。由于篇幅限制,本文就借鉴专家理论研究并结合我多年工程设计实践经验,展开暖通给排水专业配合有效探析。
【关键词】建筑设计;水暖专业;有效配合;发挥作用
Let a professional plumbing professional with effective play the biggest role in the architectural design
Fu Yu
(Zibo City Planning and Design Institute Zibo Shandong 255000)
【Abstract】With the rapid development of modern urban construction, people meet the basic functions of living space not only have unconventional appearance, but also have sound internal facilities under the premise of quality comfort and ancillary facilities construction requirements are gradually high. While the heating system, water supply and drainage systems, air conditioning and ventilation systems are also put forward higher requirements. A cozy building not only the needs of each professional designers carefully designed to do their job, but also depends on the close cooperation between them. Due to space limitations, this paper combines theoretical study and learn from experts in my many years of engineering experience, expand HVAC professional with effective drainage Analysis.
【Key words】Architectural design;Plumbing professionals;Effective coordination;Role
1. 正视建筑设计中暖通与给排水存在质量问题
(1)随着生活水平的提高,人们对住宅的要求越来越高,住宅的定义已从最初的“能挡风遮雨的处所”被提升为“放松心情、蓄锐养精的舒适港湾”;作为暖通、给排水设计人员,我们必然会遇到越来越多的新课题去面对,碰到不断出现的新问题去解决。虽然近些年我国的给排水工程与暖通工程随着建筑业的发展而取得了很大发展和进步,但是在实践中仍然存在许多亟待改进和解决的问题。首先,从给排水工程方面看,常见的质量问题主要出现在安装管道支架不够牢固、给水立管同墙距离不够、水质不合格、采用不合格的龙头、按照前未进行消毒处理等问题。另外,由于我国目前的房屋工程在给水施工时多采用PPR管,而这类管材在使用中的缺陷主要是刚性差、易变形,从而易引发给排水管道的渗漏。而排水工程中的主要问题则是漏设管道支架、错误安装或漏设伸缩节,从而导致的一系列渗漏现象。同时,我国的建筑工程在进行给排水安装的过程中,一般来说都没有设置检漏井,通常只有检查井,这样不仅不利于工作人员的巡检,还会引起卫生洁具的牢固性不足和平整度不高的外观问题。
(2)其次,建筑暖通工程中常见的质量问题则主要表现为风管漏风量大、无直角、风管表面不平整、安装质量不高、观感效果不佳等。除此之外,暖通工程中的空调管道还经常会出现漏水和渗水的现象,给系统的正常运行和检修人员的维修都造成了不便。而造成这些现象的原因则主要是法兰、垫片、风管之间的闭合不够严密,以及丝口拧紧不到位等。
2. 有效暖通与给排水专业配合策略探究
2.1 与建筑专业的配合。
2.1.1 对于一个功能健全的暖通给排水作业工程而言,由于吊顶净空空间着实有限,加上不同技术工种专业的施工要求也略有不同。因此,在处理暖通专业涉及到的新风管、回风管、排风管、冷凝管等管路或管线问题时,应确保其余给排水作业中设计到的给水管、污水管、喷淋管的管网布设交叉作业时能够顺利进行。因此,在必要的建筑设计过程中,相关工程设计师或者技术设计人员应当对施工作业内的各安装构件尺寸、构件标高、主要安装工艺等要特别加以详细标注,其目的是保障作业质量的同时,能够为各个专业工种间的作业进行提供技术配合、协调的空间。此外,如果各技术工种、专业施工出现矛盾时或者不能及时协调时,也应当按照业主设计意图、施工图设计意图进行合理协调,最好由业主出面作为协调人,同时在协调过程中要按照设备及构件安装说明、土建作业施工规范、暖通给排水专业技术规范等内容加以对照分析,以保证最终协调过程中的设计及施工结果得以匹配,避免后期重修、返工或者施工临时变更等的发生。
2.1.2 对厨房、卫生问布置的要求。建筑设计人员在建筑平面设计上应注意竖向功能,尽可能地做到:(1)上、下层建筑厨房、卫生间位置一致。(2)避免卫生间位于厨房上面,当条件限制不能避免时,应采取防护措施。(3)厨房、卫生同等用水设备不得布置在变电室、备用发电机房的上面。(4)要注意让排水立管留有适当位置 。(5)地下室为人防,上部尽可能不设卫生 间等。如需设置,底层地面与地下人防顶之闫应加垫层 。如:空调冷凝水排放问题的解决。现在设计施工过程中更加注意空调冷凝水排放引起的问题。多采用每层室外空调机板加冷凝水排水立管的设计,为室外机设置单独的排水立管,排水并散流至附近雨水口。空调排水管常选用PVC-U类型排水管,为每层室外空调机预留排水用接口三通,利于空调排水软管直接接入。
2.2 与结构专业的配合。
(1)结构专业可以是一栋建筑设计的“生命”专业。这就要求与结构专业的配合必须周密 、慎重。作为暖通、给排水专业的设计人员,在设计一开始就应在方案成形后,尽快给结构专业提供所有设备的重量及基础,尤其是较重的大型设备,更不能遗漏。例如:制冷机组 、水泵等设备的基础;设备层内设备问空调机组等设备的重量;水箱间内生活水箱、膨胀水箱 的重量等等。
(2)在设计进行中,在系统范围划分完毕,管道走向明确以后,就要在需要穿梁楼板、剪力墙处,为结构专业预留孔洞。一般楼板上的孔洞可在DN >200ram 以上的预留,其余穿楼板的小孔洞,可以在土建施工过程中,水暖工作人员与土建人员协作预留。现在高层建筑剪力墙结构很多,剪力墙上的所有的孔洞均要预留,这就要求设备专业人员要认真配合,避免因为遗漏剪力墙及梁上的孔洞给施工带来困难,甚至出现问题。因为剪力墙内的暗柱及结构梁有些地方是不允许开洞的。若遇此问题我们设备专业的管道走向只能改道而行。引自(至)室外的管线,需预留进(出)入孔洞;需在地沟内敷设管线的建筑,要及时给结构专业提供检查井及地沟的位置、尺寸。需要吊顶安装的设备,例如:大门热风幕,吊顶空调机组,要向结构专业提供所需设预埋件的位置。
3. 总而言之
对整个建筑工程来说,暖通给排水施工作业涉及到的每项工序都是保障现代建筑基本功能、安全价值得以发挥的基本操作单元,它们之间设计安装工程有效配合对整个建筑物的运行和人们生活质量的提高有着重要影响。因此,在建筑设计中非常有必要加强和暖通给排水有重要关联的技术专业内容研究,今后在实际工作中,我们需要认识存在的常见问题,与时俱进不断学习先进技术以提高暖通及给排水工程质量,促进整个建筑工程更好的运行和工作,为人们的生产生活创造良好的条件。
参考文献
[1] 张芬兰.暖通及给排水设计安装工程常见问题之浅见[J].北京建筑,2013.9 .
[2] 王丽娟. 浅谈暖通给排水设计与建筑工程中的质量问题预防措施[J].门窗,2013.12.
【关键词】建筑设计;水暖专业;有效配合;发挥作用
Let a professional plumbing professional with effective play the biggest role in the architectural design
Fu Yu
(Zibo City Planning and Design Institute Zibo Shandong 255000)
【Abstract】With the rapid development of modern urban construction, people meet the basic functions of living space not only have unconventional appearance, but also have sound internal facilities under the premise of quality comfort and ancillary facilities construction requirements are gradually high. While the heating system, water supply and drainage systems, air conditioning and ventilation systems are also put forward higher requirements. A cozy building not only the needs of each professional designers carefully designed to do their job, but also depends on the close cooperation between them. Due to space limitations, this paper combines theoretical study and learn from experts in my many years of engineering experience, expand HVAC professional with effective drainage Analysis.
【Key words】Architectural design;Plumbing professionals;Effective coordination;Role
1. 正视建筑设计中暖通与给排水存在质量问题
(1)随着生活水平的提高,人们对住宅的要求越来越高,住宅的定义已从最初的“能挡风遮雨的处所”被提升为“放松心情、蓄锐养精的舒适港湾”;作为暖通、给排水设计人员,我们必然会遇到越来越多的新课题去面对,碰到不断出现的新问题去解决。虽然近些年我国的给排水工程与暖通工程随着建筑业的发展而取得了很大发展和进步,但是在实践中仍然存在许多亟待改进和解决的问题。首先,从给排水工程方面看,常见的质量问题主要出现在安装管道支架不够牢固、给水立管同墙距离不够、水质不合格、采用不合格的龙头、按照前未进行消毒处理等问题。另外,由于我国目前的房屋工程在给水施工时多采用PPR管,而这类管材在使用中的缺陷主要是刚性差、易变形,从而易引发给排水管道的渗漏。而排水工程中的主要问题则是漏设管道支架、错误安装或漏设伸缩节,从而导致的一系列渗漏现象。同时,我国的建筑工程在进行给排水安装的过程中,一般来说都没有设置检漏井,通常只有检查井,这样不仅不利于工作人员的巡检,还会引起卫生洁具的牢固性不足和平整度不高的外观问题。
(2)其次,建筑暖通工程中常见的质量问题则主要表现为风管漏风量大、无直角、风管表面不平整、安装质量不高、观感效果不佳等。除此之外,暖通工程中的空调管道还经常会出现漏水和渗水的现象,给系统的正常运行和检修人员的维修都造成了不便。而造成这些现象的原因则主要是法兰、垫片、风管之间的闭合不够严密,以及丝口拧紧不到位等。
2. 有效暖通与给排水专业配合策略探究
2.1 与建筑专业的配合。
2.1.1 对于一个功能健全的暖通给排水作业工程而言,由于吊顶净空空间着实有限,加上不同技术工种专业的施工要求也略有不同。因此,在处理暖通专业涉及到的新风管、回风管、排风管、冷凝管等管路或管线问题时,应确保其余给排水作业中设计到的给水管、污水管、喷淋管的管网布设交叉作业时能够顺利进行。因此,在必要的建筑设计过程中,相关工程设计师或者技术设计人员应当对施工作业内的各安装构件尺寸、构件标高、主要安装工艺等要特别加以详细标注,其目的是保障作业质量的同时,能够为各个专业工种间的作业进行提供技术配合、协调的空间。此外,如果各技术工种、专业施工出现矛盾时或者不能及时协调时,也应当按照业主设计意图、施工图设计意图进行合理协调,最好由业主出面作为协调人,同时在协调过程中要按照设备及构件安装说明、土建作业施工规范、暖通给排水专业技术规范等内容加以对照分析,以保证最终协调过程中的设计及施工结果得以匹配,避免后期重修、返工或者施工临时变更等的发生。
2.1.2 对厨房、卫生问布置的要求。建筑设计人员在建筑平面设计上应注意竖向功能,尽可能地做到:(1)上、下层建筑厨房、卫生间位置一致。(2)避免卫生间位于厨房上面,当条件限制不能避免时,应采取防护措施。(3)厨房、卫生同等用水设备不得布置在变电室、备用发电机房的上面。(4)要注意让排水立管留有适当位置 。(5)地下室为人防,上部尽可能不设卫生 间等。如需设置,底层地面与地下人防顶之闫应加垫层 。如:空调冷凝水排放问题的解决。现在设计施工过程中更加注意空调冷凝水排放引起的问题。多采用每层室外空调机板加冷凝水排水立管的设计,为室外机设置单独的排水立管,排水并散流至附近雨水口。空调排水管常选用PVC-U类型排水管,为每层室外空调机预留排水用接口三通,利于空调排水软管直接接入。
2.2 与结构专业的配合。
(1)结构专业可以是一栋建筑设计的“生命”专业。这就要求与结构专业的配合必须周密 、慎重。作为暖通、给排水专业的设计人员,在设计一开始就应在方案成形后,尽快给结构专业提供所有设备的重量及基础,尤其是较重的大型设备,更不能遗漏。例如:制冷机组 、水泵等设备的基础;设备层内设备问空调机组等设备的重量;水箱间内生活水箱、膨胀水箱 的重量等等。
(2)在设计进行中,在系统范围划分完毕,管道走向明确以后,就要在需要穿梁楼板、剪力墙处,为结构专业预留孔洞。一般楼板上的孔洞可在DN >200ram 以上的预留,其余穿楼板的小孔洞,可以在土建施工过程中,水暖工作人员与土建人员协作预留。现在高层建筑剪力墙结构很多,剪力墙上的所有的孔洞均要预留,这就要求设备专业人员要认真配合,避免因为遗漏剪力墙及梁上的孔洞给施工带来困难,甚至出现问题。因为剪力墙内的暗柱及结构梁有些地方是不允许开洞的。若遇此问题我们设备专业的管道走向只能改道而行。引自(至)室外的管线,需预留进(出)入孔洞;需在地沟内敷设管线的建筑,要及时给结构专业提供检查井及地沟的位置、尺寸。需要吊顶安装的设备,例如:大门热风幕,吊顶空调机组,要向结构专业提供所需设预埋件的位置。
3. 总而言之
对整个建筑工程来说,暖通给排水施工作业涉及到的每项工序都是保障现代建筑基本功能、安全价值得以发挥的基本操作单元,它们之间设计安装工程有效配合对整个建筑物的运行和人们生活质量的提高有着重要影响。因此,在建筑设计中非常有必要加强和暖通给排水有重要关联的技术专业内容研究,今后在实际工作中,我们需要认识存在的常见问题,与时俱进不断学习先进技术以提高暖通及给排水工程质量,促进整个建筑工程更好的运行和工作,为人们的生产生活创造良好的条件。
参考文献
[1] 张芬兰.暖通及给排水设计安装工程常见问题之浅见[J].北京建筑,2013.9 .
[2] 王丽娟. 浅谈暖通给排水设计与建筑工程中的质量问题预防措施[J].门窗,2013.12.