字盘秤的计量就是表盘上指针转动一定角度的计量。现仅就指针轴心与表盘圆心不同心时所产生的角度变化进行分析。由于指针与表盘装配定位时,一般都是装配人员利用目测指针尖与分度基圆的间距进行的,要保证同心有一定困难,因此指针轴心与表盘圆心总存在一个偏差。这一偏差将随指针转角的变化而变化,使测量误差(角度误差)呈正弦曲线规律出现并存在。一、偏心造成的测量误差当指针轴心O′和表盘圆心O存在一个偏差量e时,指针在一定的秤量下转动相应的α角(见图1),即会产生一个测量误差。由正弦定理可知: 当∠A很小时,可把sinA当作测量误
Dial scale is the measurement of the dial pointer rotation angle measurement. Now only the pointer axis and the dial center of the heart is not generated when the angle of change. As the pointer and dial assembly positioning, the assembly staff are generally used visual pointer tip and indexing base circle spacing to ensure concentric have some difficulties, so the pointer axis and the dial center there is always a deviation. This deviation will change with the change of pointer angle, so that the measurement error (angle error) appears as a sinusoidal law and exist. First, the measurement error caused by eccentric When the pointer axis O ’and the dial center O there is a deviation e, the pointer in a certain amount of rotation of the corresponding α angle (see Figure 1), which will produce a measurement error. From the sine theorem we can see: When ∠A is small, sinA can be used as a measurement error