我们在先前的文章中曾介绍对原发性闭角型青光眼和正常眼的一些测定研究,证实了眼的解剖结构异常是原发性闭角型青光眼的发病基础.为更精确地进行活体结构测定研究,我们采用高频(15兆赫)聚焦起声探头测定,对闭角型青光眼晶体厚度与轴长的关系以及不同类型闭角青光眼作深入研究,现将结果报告如下: 一、材料和方法 (一)材料:检查对象来自本中心医院病房及门诊,经临床检查确诊为原发性闭角青光眼142例266眼
We have introduced in previous articles some of the primary angle-closure glaucoma and normal eye measurements study confirmed that anatomical abnormalities of the eye is the basis for the pathogenesis of primary angle-closure glaucoma in order to more accurately carry out the living structure Determination of the study, we use high-frequency (15 MHz) focused acoustics probe determination of angle-closure glaucoma crystal thickness and axial length as well as different types of angle closure glaucoma for further study, the results are reported as follows: First, materials and methods (A) Material: The test object from the center of the hospital wards and clinics, clinically diagnosed as primary angle-closure glaucoma in 142 cases of 266 eyes