论文部分内容阅读
日本三菱公司长崎研究所在1957年建立了煤粉试验装置,并在该装置上进行了锅炉及各种工业炉的燃烧及燃烧器的研究工作。为了适应今后大型燃烧研究工作的需要,在1970年建立了新的燃烧试验室,在试验室中备有新建的及原有的试验炉,作为燃烧研究的中心。(1)设备概况在燃烧试验室中,有三台不同容量的燃烧试验炉,其中最大的试验炉每小时耗油量为8吨,可用于100~150万瓩级电站锅炉的实际燃烧器试验研究,设备规格见表1。其它试验炉的耗油量为2吨,进行四角及前墙燃烧试验。
Japan’s Mitsubishi Corporation Nagasaki Institute established in 1957 coal pulverized coal testing plant, and in the device on the boiler and a variety of industrial furnace combustion and burner research. In order to meet the needs of large-scale combustion research in the future, a new combustion laboratory was established in 1970, and new and original test furnaces were installed in the laboratory as a center of combustion research. (1) Equipment Overview In the combustion laboratory, there are three different combustion test furnaces, of which the largest test furnace consumes 8 tons of fuel per hour, and can be used for 100-150 million 瓩 class boiler experiments with actual burners , Equipment specifications in Table 1. Other test furnace fuel consumption of 2 tons, four corners and the front wall burning test.