A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird

来源 :中华医学杂志(英文版) | 被引量 : 0次 | 上传用户:luluxxx
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Background Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice.Methods In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents(n=93, Firebird group) or Excel stents (n=97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization),binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups.Results Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P> 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 ± 0.21) mm versus (0.14 ± 0.20) mm (P=0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group.There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital.Conclusions Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCl in daily practice.
其他文献
目前,干细胞应用于临床治疗缺血性心脏疾病已取得了一定的疗效.然而干细胞移植后的的动态变化难以被量化,同时干细胞在体内的过程及其作用机理尚不清楚.分子影像作为一门新兴
经济全球化使得大型企业对外需要塑造新的客户关系,对内需要对日益退化的企业组织架构进行创新。本文介绍和分析大型企业宝钢集团的"总监制"组织建构创新的过程和内容,以期为
Pancreatic tumors are primary in most of the cases. Pancreatic metastases associated with other primary malignancies, especially pancreatic metastasis of leiomy
AIM: To explore the molecular mechanisms of action of paclitaxel and NM-3 on human gastric cancer in severe combined immune deficiency (SCID) mice.METHODS: Huma
Hilar tumors have proven to be a challenge to treat and manage because of their poor sensitivity to conventional therapies and our inability to prevent or to de
AIM: To compare the antiviral efficacy of adefovir (ADV) in lamivudine (LMV)-resistant patients with LMV treatment in nucleoside-na(i)ve patients, using serum s
It has been accepted that bone marrow transplantation (BMT)is the only curative therapeutic option for certain hematologic malignancies.The southeast Asia regio
AIM: To conduct a detailed histological study of gastritis in adult patients attending an endoscopy clinic at a Kenyan teaching and referral hospital.METHODS: B
Background Human embryonic stem cells can propagate indefinitely in vitro and are able to differentiate into derivatives of all three embryonic germ layers. The
Prolonged cholestasis is a very rare complication of endoscopic retrograde cholangiography (ERC). Only few cases with this complication are reported in the Engl