论文部分内容阅读
摘要:我矿大多数监控分站的电源开关在上一级电源停电之后,需要人工现场送电才能恢复其正常工作,若不及时人工送电,分站就会因直流耗尽导致自动关机,分站所带载的各类传感器直接失去监控功能,严重威胁着矿井的安全生产。为此,我们根据监控分站供电开关的送电原理,利用监控系统继电器控制功能,成功实现了分站电源远程控制送电方案。
关键词:分站 ,电源 ,远程控制, 送电, 方案
Abstract: I mine most of the power switch in monitoring stations on the power level after a power outage, need artificial transmission to the resume their normal work, if not timely artificial transmission, RACES will run out for dc in the automatic shutdown, RACES with years of each kind of sensor losing monitoring function directly and threatening the mine safety production. For this, we according to the monitoring stations of the power supply switch transmission principle, the use of monitoring system relay control function, achieve the power transmission scheme remote control RACES.
Keywords: stations, power, and remote control, transfer scheme
中图分类号: U283 文献标识码:A 文章编号:
一、引言
目前,我矿安全监控系统分站电源供电大多取自各掘进工作面备用局扇开关、移变低馈或变电所内照明综保等开关的电源侧,若上级电源开关检修或意外掉电,分站就处于直流供电状态,若不及时到现场对分站电源供电开关进行人工送电,分站就会因直流耗尽导致自动关机,从而切断被控区域内所有非本质安全型电气设备电源,并且现场所有传感器全部停止运行,直接失去安全监控功能,严重威胁着矿井的安全生产。为此,在监控分站交流供电停止后,井下安全监测工巡检人员不能及时到达现场进行手动送电的情况下,我们探索并实现一种免人工送电方法——分站电源在监控系统中心站进行远程送电。
2分站电源供电开关在使用过程中存在的问题
我矿安全监控系统共计带载监控分站58台,而监控分站电源的供电开关有多种,其中使用最多的两种是QJZ-35、QBZ-80型开关。以上两种类型开关在使用过程中存在如下问题:
2.1开关上一级电源掉电后,需要人工进行复电才能恢复正常工作。
2.1之前,一旦監控系统中心站发出分站直流供电报警声音后,值班人员就得立即电话通知现场监测工,监测工为流动工种,往往通知到人时已经过去很长时间,加上路途遥远,甚至有的分站在监测工还未到现场就直流耗尽而中断,现场失去监控,影响生产;
2.2为了给分站电源送电,必须安排现场监测工停下手头活,抓紧时间赶到现场,耽误了监测工正常的巡检维护工作,消耗了大量人力、物力和时间。
3分站电源远程送电的实现方法
为了保证分站电源供电开关掉电以后,能够及时恢复开关供电,我们在不改变开关原有结构的情况下,根据开关的送电原理,我们将远程断电控制器的断电触点接入开关的辅助送电触点,并将远程断电控制器接入分站,然后在系统设置相应送电继电器测点号,从而形成远程控制回路。这样,在分站电源开关掉电以后,我们只需在监控系统中心站向送电继电器发送手控指令,使该继电器动作,促使开关的辅助触点闭合,从而使开关的复位触点接触,开关合闸,电源送电。相当于将开关送电按钮设置在监控系统中心站,只需中心站值班人员鼠标一点击即可送电,很方便地就解决了开关送电的问题。只需1台远程断电器和3米监控电缆即可实现以上目标,安装接线非常简单。
分站电源在监控中心站远程送电的安装接线示意图如下:
4分站电源远程送电的优点
4.1分站电源供电开关掉电,无需安排人员到现场送电,足不出户,只需在监控系统中心站点击鼠标即可送电,节约了大量人力、物力和时间;
4.2分站电源供电开关掉电以后,只要上一级电源开关一送电,我们就能够在第一时间给监控分站供上交流电,最大限度地减少了分站直流供电时间,从而减少了直流耗尽隐患,保证了监控电源的稳定供电,确保了监控系统的安全稳定运行;
4.3若上级电源开关检修或意外故障超过分站的直流供电时间时,分站就会因备用电源直流耗尽而中断,当分站的上一级电源开关送电时,分站电源开关的送电继电器得电后动作,从而自动给监控分站送电,无需在监控系统中心站远程送电,更不需现场人工送电。
5分站电源远程送电所产生的效益
对于煤矿来说,安全就是最大的效益。安全在煤矿里是一票否决,哪怕掘进进尺再多,原煤产量再高,没有了安全,那一切都只是一句空话。我们在采用这种方法以后,最大限度的保证了监控分站的稳定供电,保证了监控系统的稳定运行,从而保证了对矿井各地点瓦斯情况不间断地密切监控,及时准确的掌握井下各地点的瓦斯变化情况及生产情况,一旦瓦斯浓度超过断电值,监控系统就能够迅速切断该地点的一切电源,从而避免事故的进一步扩大。
6结束语
免人工送电之——矿井安全监控系统分站电源远程送电在未改变电源供电开关任何参数的情况下,只需在监控系统中心站下发手控命令,就可以使监控分站由直流供电及时地转换为交流供电,节约了大量的人力、物力和时间。采取远程送电以后,我们的监控分站再也没有出现过因无人送电或送电不及时造成的分站中断现象,确保了监控系统安全稳定运行,保障了矿井的安全生产。
参考文献:
[1] 博文.固态继电器[J].电子世界,2007(6):9-10.
[2] 聂培毓;煤矿安全监控系统问题的论述[J];山西焦煤科技;2003年01期
作者简介:
李飞,男,(1986-),安徽理工大学电子信息工程专业毕业,本科学历,2007年7月参加工作,助理工程师,现任淮南矿业集团谢桥煤矿监测队副队长。
注:文章内所有公式及图表请以PDF形式查看。
关键词:分站 ,电源 ,远程控制, 送电, 方案
Abstract: I mine most of the power switch in monitoring stations on the power level after a power outage, need artificial transmission to the resume their normal work, if not timely artificial transmission, RACES will run out for dc in the automatic shutdown, RACES with years of each kind of sensor losing monitoring function directly and threatening the mine safety production. For this, we according to the monitoring stations of the power supply switch transmission principle, the use of monitoring system relay control function, achieve the power transmission scheme remote control RACES.
Keywords: stations, power, and remote control, transfer scheme
中图分类号: U283 文献标识码:A 文章编号:
一、引言
目前,我矿安全监控系统分站电源供电大多取自各掘进工作面备用局扇开关、移变低馈或变电所内照明综保等开关的电源侧,若上级电源开关检修或意外掉电,分站就处于直流供电状态,若不及时到现场对分站电源供电开关进行人工送电,分站就会因直流耗尽导致自动关机,从而切断被控区域内所有非本质安全型电气设备电源,并且现场所有传感器全部停止运行,直接失去安全监控功能,严重威胁着矿井的安全生产。为此,在监控分站交流供电停止后,井下安全监测工巡检人员不能及时到达现场进行手动送电的情况下,我们探索并实现一种免人工送电方法——分站电源在监控系统中心站进行远程送电。
2分站电源供电开关在使用过程中存在的问题
我矿安全监控系统共计带载监控分站58台,而监控分站电源的供电开关有多种,其中使用最多的两种是QJZ-35、QBZ-80型开关。以上两种类型开关在使用过程中存在如下问题:
2.1开关上一级电源掉电后,需要人工进行复电才能恢复正常工作。
2.1之前,一旦監控系统中心站发出分站直流供电报警声音后,值班人员就得立即电话通知现场监测工,监测工为流动工种,往往通知到人时已经过去很长时间,加上路途遥远,甚至有的分站在监测工还未到现场就直流耗尽而中断,现场失去监控,影响生产;
2.2为了给分站电源送电,必须安排现场监测工停下手头活,抓紧时间赶到现场,耽误了监测工正常的巡检维护工作,消耗了大量人力、物力和时间。
3分站电源远程送电的实现方法
为了保证分站电源供电开关掉电以后,能够及时恢复开关供电,我们在不改变开关原有结构的情况下,根据开关的送电原理,我们将远程断电控制器的断电触点接入开关的辅助送电触点,并将远程断电控制器接入分站,然后在系统设置相应送电继电器测点号,从而形成远程控制回路。这样,在分站电源开关掉电以后,我们只需在监控系统中心站向送电继电器发送手控指令,使该继电器动作,促使开关的辅助触点闭合,从而使开关的复位触点接触,开关合闸,电源送电。相当于将开关送电按钮设置在监控系统中心站,只需中心站值班人员鼠标一点击即可送电,很方便地就解决了开关送电的问题。只需1台远程断电器和3米监控电缆即可实现以上目标,安装接线非常简单。
分站电源在监控中心站远程送电的安装接线示意图如下:
4分站电源远程送电的优点
4.1分站电源供电开关掉电,无需安排人员到现场送电,足不出户,只需在监控系统中心站点击鼠标即可送电,节约了大量人力、物力和时间;
4.2分站电源供电开关掉电以后,只要上一级电源开关一送电,我们就能够在第一时间给监控分站供上交流电,最大限度地减少了分站直流供电时间,从而减少了直流耗尽隐患,保证了监控电源的稳定供电,确保了监控系统的安全稳定运行;
4.3若上级电源开关检修或意外故障超过分站的直流供电时间时,分站就会因备用电源直流耗尽而中断,当分站的上一级电源开关送电时,分站电源开关的送电继电器得电后动作,从而自动给监控分站送电,无需在监控系统中心站远程送电,更不需现场人工送电。
5分站电源远程送电所产生的效益
对于煤矿来说,安全就是最大的效益。安全在煤矿里是一票否决,哪怕掘进进尺再多,原煤产量再高,没有了安全,那一切都只是一句空话。我们在采用这种方法以后,最大限度的保证了监控分站的稳定供电,保证了监控系统的稳定运行,从而保证了对矿井各地点瓦斯情况不间断地密切监控,及时准确的掌握井下各地点的瓦斯变化情况及生产情况,一旦瓦斯浓度超过断电值,监控系统就能够迅速切断该地点的一切电源,从而避免事故的进一步扩大。
6结束语
免人工送电之——矿井安全监控系统分站电源远程送电在未改变电源供电开关任何参数的情况下,只需在监控系统中心站下发手控命令,就可以使监控分站由直流供电及时地转换为交流供电,节约了大量的人力、物力和时间。采取远程送电以后,我们的监控分站再也没有出现过因无人送电或送电不及时造成的分站中断现象,确保了监控系统安全稳定运行,保障了矿井的安全生产。
参考文献:
[1] 博文.固态继电器[J].电子世界,2007(6):9-10.
[2] 聂培毓;煤矿安全监控系统问题的论述[J];山西焦煤科技;2003年01期
作者简介:
李飞,男,(1986-),安徽理工大学电子信息工程专业毕业,本科学历,2007年7月参加工作,助理工程师,现任淮南矿业集团谢桥煤矿监测队副队长。
注:文章内所有公式及图表请以PDF形式查看。