Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coro

来源 :华中科技大学学报(医学英德文版) | 被引量 : 0次 | 上传用户:shgrx
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
Whether the localized flow acceleration occurs in the resting stenotic left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated.Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoracic color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow.There were 23 patients with localized acceleration flow examined by echocardiography. Twenty of them were found to have luminal diameter stenosis (60 %- 98 %) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by echocardiography. Eighteen of them had no or <60% stenosis. Four patients had serious stenosis (≥95 %) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P<0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P<0.01). The specificity by using the ratio≥1.5 for stenosis detection was 85.7 % (18/21), and the sensitivity was 83.3 % (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotic left anterior descending coronary artery. Transthoracic color Doppler echocardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery.
其他文献
The chronological and spatial rules of changes during focal cerebral ischemia and reperfusion in different brain regions with magnetic resonance diffusion-weigh
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
该文从挂篮荷载计算、施工流程、支座及临时固结施工、挂篮安装及试验、合拢段施工、模板制作安装、钢筋安装、混凝土的浇筑及养生、测量监控等方面人手,介绍了S226海滨大桥
在射线探伤专业培训中,射线探伤工艺及编制占有重要的份额.但针对工件的专用探伤工艺编制和工艺卡的设计与填写,目前缺乏合适的教材与范例,在课堂上要想真正讲解清楚尚属不易
近日,第十四届中国国际公共安全博览会(简称安博会)在深圳会展中心闭幕。超视科技凭借“超视”视频集中监控管理平台,吸引了众多参观者、行业合作伙伴及潜在客户的关注。据了
本文结合实际井下调研、理论分析及现场验证等,对井下巷道顶板结构破坏的原因进行了分析,同时针对性的提出了控制方案,根据在某矿的实际应用表明,顶板发生破坏的主要原因是顶
该文通过定义的分析比较,提出运行风险评估和传统电力可靠性的数学模型本质上是一致的,其区别之处在于应用场景不同.该文分析了运行风险评估在可靠性原理、调度自动化技术和
The different sera proteomic components between uremia patients and normal subjects were studied through two-dimensional gel electrophoresis technique. Immobili
与往常上班一样,周蔚伟被清晨熟悉的闹钟叫醒,简单的梳洗,穿着好海事制服,她轻轻地给仍在熟睡的孩子掖掖被子,准备出门.今天是2017年1月27日,大年三十,作为九江新港海事处政
期刊
The demand for knowledge of productive health and the current status of productive health services provided by relevant govmental institutions were qualitativel