Miniature Fabry-Perot interferometric sensor for temperature measurement based on photonic crystal f

来源 :OptoelectronicsLetters | 被引量 : 0次 | 上传用户:DGFIDYRSTG
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
A novel miniature Fabry-Perot interferometric (FPI) temperature sensor is proposed and demonstrated experimentally. The modal interferometer is fabricated by just splicing a section of photonic crystal fiber (PCF) with a single-mode fiber (SMF). The air holes of the PCF are fully collapsed by the discharge arc during the splicing procedure to enhance the reflection coefficient of the splicing point. The transmission spectra with different temperatures are measured, and the experimental results show that the linear response of 11.12 pm/°C in the range of 30–80 °C is obtained. This sensor has potential applications in temperature measurement field.
其他文献
用CO2及N2激光以不同时间处理水稻种子及洋葱鳞茎的根和芽,发现细胞质膜、内质网、核糖核蛋白体、线粒体的光效应最大;造粉体、溶酶体次之;液泡膜的光效应最小.据此讨论了激光在诱变育种和治疗肿瘤方面应用的可能性.试验还测定了两种激光的一些剂量对植物组织的穿透力.
期刊
针对相位敏感光时域反射仪(Φ-OTDR)信号信噪比较低的问题, 提出了一种基于自适应噪声完备经验模态分解(CEEMDAN)的小波信息熵阈值去噪算法。该算法配合CEEMDAN分解, 通过小波信息熵阈值去噪, 提取扰动位置的高频信息, 从而提高系统的信噪比。首先, 采用Savitzky-Golay滤波算法对不同光脉冲间的信号进行预处理; 其次, 采用CEEMDAN将滑动差分后单个脉冲内信号分解为不同的固有模态函数(IMF), 并利用连续均方误差准则确定含噪较多的高频IMF分量; 然后, 采用小波信息熵阈值去噪
The article provides information about the image on the cover of Advanced Photonics, Volume 2, Issue 4.
期刊
The authors would like to apologize for an error in our paper in Chin. Opt. Lett. 15(10), 100604 (2017).
本文提出将银盐振幅型全息图先漂白成氯化银全息图,再经强光照射转变为银微粒位相型全息图的光分解银方法.用天津I型全息干版,衍射效率可达28%,并对光照稳定.电子显微镜照片显示出光解银的线度为0.01μm数量级,从而解释了本方法提高衍射效率的原因.
期刊
对三维光纤布拉格光栅(FBG)应变传感器的温度补偿问题进行研究,设计了新型温度补偿膜片,并采用参考光纤法对传感器进行温度补偿。实验发现,未经老化处理的裸纤在30~40℃之间会出现温度拐点,致使温度灵敏系数降低,所以封装之前必须进行老化处理。通过有限元热力分析可知,新型温度补偿膜片在-10~50℃之间自身的最大微应变约为0.073με,受热膨胀系数失配的影响较小,系统的可靠性较高。同时悬臂梁式的缓存
期刊
An effective mode selection is important for the multi-core photonic crystal fiber (PCF) to obtain good output. Talbot cavity is popular to lock the in-phase mode, but few satisfactory experimental results have been reported. In this paper, a dual-Talbot
期刊
The contrast mechanism of different polarization imaging techniques for melanoma in mouse skin is studied using both experiments and Monte Carlo simulations. Total intensity, linear polarization difference imaging (DPI), degree of polarization imaging (DO
In vivo fiber photometry is a powerful technique to analyze the dynamics of population neurons during functional study of neuroscience. Here, we introduced a detailed protocol for fiber photometry-based calcium recording in freely moving mice, covering fr