论文部分内容阅读
With the help of the modified geometrical factor theory, the Marquardt method was used to calculate the true electrical parameters of the formation from array induction logs. The inversion results derived from the assumed model and some practical cases show that the rebuilt formation profile determined by 2-ft resolution array induction logs is reasonable when the formation thickness is greater than 1 m, which thus indicates that the inversion method is reliable and can provide quantitative information for the discrimination of oil/gas or water zone.