论文部分内容阅读
30例脆性糖尿病患者均采用胰岛素泵(CSII)治疗,全部患者随机平均分为2组,分别采用每日8次微量血糖仪血糖监测(A组)和实时动态血糖监测方法(B组)对其血糖进行监测,比较两组血糖稳定达标时间、发现无感知低血糖次数、血糖漂移幅度和住院时间的差异,评价血糖监测方法的优越性。结果实时动态血糖监测组易发现低血糖事件,调整治疗方案所需时间短,血糖漂移幅度小。结论实时动态血糖监测系统对于脆性糖尿病治疗具有显著的优越性。
Thirty patients with fragile diabetes were treated with insulin pump (CSII). All the patients were randomly divided into two groups. The blood glucose level was monitored by blood glucose meter (A group) and real-time dynamic glucose monitoring group (B group) Blood glucose monitoring, blood glucose was stable than the two standard time, found no sense of hypoglycemia, blood glucose drift and hospital stay difference, evaluation of blood glucose monitoring methods superiority. Results In the real-time dynamic glucose monitoring group, hypoglycemic events were easily found, the time needed to adjust the treatment plan was short, and the blood sugar drift was small. Conclusion The real-time dynamic blood glucose monitoring system has obvious advantages for the treatment of brittle diabetes.