论文部分内容阅读
本文以南宁市某医院为例,针对目前最常用的两种集中式冷暖空调设计方案均存在的一些不足,提出一种类似热源塔的优化设计方案,对这三种空调设计方案的初投资及运行费用进行分析比较,根据计算数据得出结论,为设计师及业主以后在选择类似项目的空调方案时提供借鉴和参考。
In this paper, a hospital in Nanning City, for example, for the most commonly used two kinds of centralized heating and cooling air conditioning design are some of the shortcomings, put forward a similar optimization of heat source tower design, the three air-conditioning design of the initial investment and Operating costs for analysis and comparison, based on the calculation data to draw conclusions for designers and owners in the future when you choose a similar project air-conditioning programs to provide reference and reference.