搜索筛选:
搜索耗时4.4138秒,为你在为你在102,285,761篇论文里面共找到 9 篇相符的论文内容
类      型:
[会议论文] 作者:Hyun-Jae Koo,Dong-Su Kim,Seong-Hee Kang,Tae-Ho Kim,Kyeong-Hyun Kim,Dong-Seok Shin,Tae-Suk Suh, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
[会议论文] 作者:Hyun-Jae Koo,Dong-Su Kim,Seong-Hee Kang,Tae-Ho Kim,Kyeong-Hyun Kim,Dong-Seok Shin,Tae-Suk Suh, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
Purpose In IMRT QA,the geometric errors(GE),which differences between the reference and measured dose distribution caused by a rotation and shift of a dose distribution because of QA environment setti...
[会议论文] 作者:Tae-Ho Kim,Siyong Kim,Dong-Su Kim,Seong-Hee Kang,Min-Seok Cho,Kyeong-Hyun Kim,Dong-Seok Shin,Tae-Suk, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
Purpose:Abdominal compression is known to be effective but,often makes external-marker-based monitoring of breathing motion not feasible.In this study,we developed and evaluated a system that enables...
[会议论文] 作者:Dong-Seok Shin,Seong-Hee Kang,Dong-Su Kim,Tae-Ho Kim,Kyeong-Hyeon Kim,Hyun-Jae Koo,Min-Seok Cho,Tae Suk, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
Purpose The difference between three-dimensional(3D)and four-dimensional(4D)dose is effected by factors such as tumor size and motion amplitude.To propose quantitative results about the effect by thes...
[会议论文] 作者:Tae-Ho Kim,Min-Seok Cho,Dong-Seok Shin,Seong-Hee Kang,Kyeong-Hyun Kim,Dong-Su Kim,Tae-Suk Suh,Siyong, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
[会议论文] 作者:Dong-Su Kim,Dong-Seok Shin,Tae-Ho Kim,Seong-Hee Kang,Tae-Suk Suh,Kyeong-Hyun Kim,Min-Seok Cho,Siyong, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
[会议论文] 作者:Dong-Su Kim,Siyong Kim,Seong-Hee Kang,Tae-Ho Kim,Kyeong-Hyun Kim,So-Hyun Park,Min-Seok Cho,Dong-Seok Shin, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
Purpose:In IMRT QA,plan quality evaluation is made based on pass rate under preset acceptance criteria,mostly using gamma-values.This method is convenient but,its result highly depends on what the acc...
[会议论文] 作者:Yu-Yun Noh,Tae-Ho Kim,Dong-Su Kim,Seong-Hee Kang,Min-Seok Cho,Kyeong-Hyun Kim,Dong-Seok Shin,Hyun-Jae, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
Purpose:To improve the set up accuracy of patient alignment,we developed a new real time patient alignment monitoring system based on laser sensing technology and evaluated its feasibility.Methods:The...
[会议论文] 作者:Seong-Hee Kang,Siyong Kim,Dong-Su Kim,Tae-Ho Kim,So-Hyun Park,Dong-Seok Shin,Min-Seok Cho,Kyeong-Hyun, 来源:The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 年份:2015
Purpose:End-of-exhale(EOE) phase is generally preferred for gating window because tumor position is more reproducible.However,other gating windows might be more appropriate for dose distribution persp...
相关搜索: