Condensing Heat Transfer Characteristics in a Quadrilobed Tube Used in Heat Pump Water Heater

来源 :2016冷冻空调亚洲大会(8th Asian Conference on Refrigeration and Air-c | 被引量 : 0次 | 上传用户:chris7520
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  In this study,condensing heat transfer in quadrilobed tubes used for a heat pump system was experimentally investigated.HFC-134a was used as the refrigerant.The effect of the tube configuration on the heat transfer coefficient was evaluated for horizontal flows in the straight and twist quadrilobed tubes.
其他文献
In the processing of machine tools,the environmental temperature of the processing area greatly influences the accuracy of the products.In order to enhance the accuracy of processing products,how to c
会议
This study developed a personal air condition seat.The cool air outlet was desgined on the top side to supply the cool air and the return air exits was design in the vicinity of the chair handle.There
会议
In this paper,experimental study on heat transfer performance of fin-tube heat exchanger and PSHE(primary surface heat exchanger)used in waste heat recovery is proceeded.The objective of this study is
会议
The purpose of this study was to compare the performance characteristics of conventional manifold of solar collectors and manifolds that are fabricated by the application of hydroforming technology.Ex
会议
In the US building sector,commercial energy use is the largest end use consuming more than nighteen quintillion Joules of source energy annually.A few studies using simulation tools to calculate build
会议
Downward two-phase flow of air and water in narrow rectangular channel has been investigated.The channel is 66.7,2.35 and 780 mm in width,gap and height,respectively.
会议
Melting in a binary solution is an important phenomenon both in environmental and engineering fields.Such melting phenomena are caused by concentration and the temperature gradient.Therefore,they are
会议
The deterioration of urban environment has a closely relationship with the functions of land use.The stagnant wind conditions in compact urban areas may also exacerbate the local environment.Instead o
会议
Thanks to advance in permanent magnet synchronous motors(PMSM)and power electronics,the household axial-type fans,such as standing fans or ceiling fans can be operated in wider speed range by using in
会议
Air-conditioning ducting has been found to be paths of smoke spread in case of fire.The interaction of air-conditioning operation and smoke exhaust has been found to be a risk factor for safe egress f
会议