对于东风_4B型机车而言,如果测速发电机CF发生故障,即使使用故障励磁也是无能为力的。据统计,我段自1987年运用该型机车以来,已有多起类似事故发生。为此,我们经过多次试验,确定了以启动发电机QD代替CF向励磁机L提供励磁电流的方法。实践证明:该方法简便易行,易于掌握。而且,不需对机车进行任何加装改造。操作时,只需要2根短接线即可,熟练者可在1分钟内处理完毕,能有效地防止事故的发生。该方法已在我段普遍推广,收到了明显效果。
For Dongfeng _4B locomotive, if the tachogenerator CF fails, even if the use of fault excitation is powerless. According to statistics, many of the similar accidents have occurred since I started using the locomotive in 1987. To this end, we have tried many times to determine the method of starting the generator QD instead of CF to the exciter L to provide excitation current. Practice has proved that this method is simple and easy to grasp. Moreover, without any modification of the locomotive. When the operation, only two short wiring can be, skilled in 1 minute processing is completed, can effectively prevent the accident. The method has been generally promoted in my paragraph, has received significant results.