一台WY—100型挖掘机,按规范磨合后,正常使用约150小时,因液压系统漏油,而实施紧急停机,故障排除后,再次起动时,不能起动.经检查发现原来是油泵供油拉杆卡死不动,油门加不上油.我们分析认为是柱塞被卡死,使调节臂不能转动所致.后拆下油泵总成,为确定故障,我们用手转油泵凸轮轴,可转动,排除了柱塞被卡死的可能,但拉杆还是不动.据此,我们打开油泵检查盖,发现供油平行拉杆几乎处于死点位置,用手推离拉杆一定距离,故障排除了,装机后,工作正常.以后,我们就注意在停机时,油门都留有一点间隙,使油泵平行拉杆不接近死点,慢慢熄火,此类故障不再发生.
A WY-100 excavator, according to the specifications after the break-in, the normal use of about 150 hours, due to hydraulic system leakage, and the implementation of emergency shutdown, troubleshooting, start again, can not start. The inspection found that the original fuel pump Lever stuck, the throttle plus oil. Our analysis is that the plunger is stuck, so that the adjustment arm can not be rotated after the removal of the pump assembly, in order to determine the fault, we use hand to pump the camshaft can be Rotary, ruled out the plunger may be stuck, but the rod still or not.Accordingly, we open the pump inspection cover and found that oil supply parallel to the rod is almost dead position, push the lever away from the distance by somebody, troubleshooting, After installed, the work is normal. Later, we pay attention to the shutdown, the throttle left a little gap, the parallel rod pull pump is not close to the dead center, slowly flameout, such failures no longer occur.