利用白沙滩泵站混流泵叶片角度可调的优势,结合泵站内外水位资料和不同运行期规定的提水量,以机组总耗电量最小为目标函数,建立了以叶片角度为决策变量的机组运行优化调度模型.运用一维离散型动态规划算法求解,得到各运行期泵站的开机台数、水泵叶片安放角、单台泵流量等.与按该站水泵设计角-2°运行相比,泵站采用该优化方案,年均可节省电能454.7万kW.h,节省电费184.1万元,节约率约为15%.可见,该方案节能效果显著,能有效降低泵站运行成本.
Taking advantage of the adjustable angle of the mixed flow pump blade at Baisha beach pump station, combining the water level data inside and outside the pump station and the amount of water required in different operation periods, the unit with the minimum total power consumption of the unit as the objective function was established. Run optimization scheduling model.Using one-dimensional discrete dynamic programming algorithm to solve, get the number of start-up units, pump blade placement angle, single pump flow, etc. in each operation period.Compared with the pump design angle -2 ° operation, Pumping station adopts this optimization plan, saving an average of 4.547 million kW.h of electricity per year and saving electricity costs of 1.841 million yuan, saving about 15%. This shows that the scheme has obvious energy-saving effect and can effectively reduce the operating costs of pumping stations.