1沼气池使用过程中的常见故障诊断与排除1.1压力表水柱上升很慢,产气量低,一时弄不清产气少还是漏气可用正负压测定。如第一天24小时内压力表水柱由零上升到10厘米,从导管处将输气管拔下来,把沼气全部放掉,在导气管处临时装一个U型压力表。从水压间内取出若干担沼液,使沼气池内变成负压。如果沼气池有漏洞池内的沼气不会漏出来,只会把池外的空气吸进去。再过24小时,把取出的沼液如数倒入水压间内,观察压力表水柱上升高度,如果与第一次水柱高度相同,说明不漏气而是产气慢;如果比第一次高了许多,说明沼气池漏气。
1 digester in the process of using the common fault diagnosis and troubleshooting 1.1 pressure gauge water column rises slowly, gas production is low, a moment can not figure out whether the gas production or less positive and negative pressure leak test. If the pressure gauge water column rises from zero to 10 cm within 24 hours on the first day, unplug the gas pipe from the pipe and release all the methane gas. Temporarily install a U-shaped pressure gauge at the gas pipe. Remove a number of biogas from the hydraulic pressure room, the digester becomes negative pressure. If the digesters have loopholes in the pool of methane will not leak out, it will only suck the air into the pool. Another 24 hours, the number of biogas taken out into the water between the pressure to observe the pressure gauge water column height, if the same height as the first water column, indicating airtight gas production but slow; if the first time Much higher, indicating biogas leakage.