目的了解医院病房灯开关的污染状况,研究其消毒的时效性。方法通过现场采样和细菌定量检测方法,对本医院病房灯开关污染状况和消毒效果进行了监测。结果该医院病房灯开关平均污染细菌数达到46cfu/cm2,污染超标率为58.7%。用有效氯浓度为500 mg/L的含氯消毒剂稀释液擦拭消毒灯开关,可达到全部合格,且可维持2d保持在卫生合格水平。结论病房内灯开关污染严重,以每2 d用含氯消毒剂擦拭消毒1次,即可保持其卫生质量合格。
Objective To understand the pollution status of hospital ward lamp switch and to study the timeliness of disinfection. Methods The on-site sampling and bacterial quantitative detection methods were used to monitor the pollution status and disinfection effect of the ward light switch in our hospital. Results The average number of bacterial contamination in the ward light switch of the hospital reached 46cfu / cm2, and the rate of pollution exceeded the standard was 58.7%. With the effective chlorine concentration of 500 mg / L of disinfectant disinfectant disinfectant wipe the switch can reach all qualified, and can maintain 2d to maintain health standards. Conclusion Ward light switch pollution is serious, every 2 days with a chlorine disinfectant wipe disinfection 1, you can maintain their health quality standards.