论文部分内容阅读
运用酪氨酸与4-氨基安替吡啉的显色反应测定食品中酪氨酸的含量。微波加热水解30s后,可在不分离其它氨基酸的条件下直接测定酪氨酸。向5mL的水解液中依次加入5mL5.0×10-2mol/L4-氨基安替比林,2.5mLNH4OH-NH4Cl缓冲溶液(pH9.40),2.5mL0.1mol/L高碘酸钠溶液,用二次水定容于50mL。显色25min后,以空白作参比,在480nm波长下测定吸光度值。浓度在6.0×10-6~1.8×10-4mol/L的酪氨酸符合比耳定律。表观摩尔吸光系数为3.03×103L/mol.cm。对含量为3.19%酪氨酸样品多次重复测量,相对标准偏差为0.42%。考察了其它氨基酸对测定的干扰。该方法测定的回收率为100.4%~102.0%。同时推测了显色反应的机理。
Determination of tyrosine in foods by chromogenic reaction of tyrosine with 4-aminoantipyrine. Tyrosine can be measured directly without separating other amino acids after microwave heating and hydrolysis for 30s. To 5 mL of the hydrolyzate, 5 mL of 5.0 × 10 -2 mol / L 4-aminoantipyrine, 2.5 mL of NH 4 OH-NH 4 Cl buffer solution (pH 9.40), 2.5 mL of 0.1 mol / L sodium periodate solution, With secondary water volume in 50mL. After 25 min of color development, the blank was used as a reference, and the absorbance value was measured at a wavelength of 480 nm. The tyrosine concentration of 6.0 × 10-6 ~ 1.8 × 10-4mol / L conforms to Beer’s law. The apparent molar absorptivity is 3.03 × 103L / mol. cm. Repeated measurements of 3.19% tyrosine sample with a relative standard deviation of 0.42%. Other amino acids were investigated for interference with the assay. The recovery of this method was 100.4% ~ 102.0%. At the same time speculated that the color reaction mechanism.