连州电厂 2台 4 2 0t/h无烟煤锅炉存在燃烧不稳 ,经常发生灭火 ,锅炉效率达不到设计值等问题 ,必须进行治理。发生上述问题的原因是 :一、二次风的布置和炉膛结构不利于无烟煤的着火和稳燃 ;空气预热器设计不合理 ;存在较大的烟气残余旋流 ;给粉不均匀 ,引起炉内燃烧波动。锅炉稳燃改造时 ,对燃烧器进行了改造 :取消中下二次风 ,缩小下一次风与中一次风间的距离 ,以利于无烟煤的着火和稳燃 ;增加卫燃带面积 ;对给粉机进行改造 ;减少高温级省煤器受热面 ;三次风改为自引式结构 ;改变油枪位置 ,减小油枪出力 ,加装 1层小油枪。改造后 8个多月的运行情况表明 ,锅炉的稳燃及其他性能取得了明显的改善 ,运行平稳。
Lianzhou Power Plant 2 420t / h anthracite boiler combustion instability, often occur fire extinguishing, boiler efficiency can not reach the design value and other issues, and must be dealt with. The reasons for the above problems are as follows: Firstly, the arrangement of the secondary air and the hearth structure are not conducive to the ignition and steady combustion of the anthracite coal; the design of the air preheater is not reasonable; there is a large residual swirling of the flue gas; Burning furnace fluctuations. The boiler stable combustion transformation, the burner has been modified: the cancellation of the secondary air, reducing the next wind and the distance between the wind, in favor of anthracite fire and stable combustion; increase the health care belt area; to the powder Machine to transform; reduce the high-temperature economizer heating surface; the third wind to self-guided structure; change the gun position, reduce the oil gun output, the installation of a small oil gun. The operation of more than 8 months after the renovation shows that the stable combustion and other properties of the boiler have been significantly improved and the operation is smooth.