目的了解兰州军区东片部队医疗机构压力蒸汽灭菌器的使用情况。方法对16家医疗卫生机构压力蒸汽灭菌器的使用情况进行现场调查,并对受检单位压力蒸汽灭菌器的灭菌效果进行现场生物学检测。结果 2006-2009年工艺监测符合要求的单位分别占68.7%、81.1%和87.5%;灭菌包化学监测符合要求的单位分别占81.1%、93.7%和100%。手术包中心部位化学监测符合要求的单位分别占56.2%、62.5%和100%;预真空压力蒸汽灭菌器B-D试验符合要求的单位4年均为100%;生物学监测符合要求的单位分别占50%、62.5%和81%。4年间,压力灭菌器现场生物学监测合格率分别为100%、81.9%、93.3%、96.6%。结论通过监督检查,兰州军区东片部队医疗机构在压力蒸汽灭菌器的规范性使用上存在的问题基本得到了解决。
Objective To understand the use of pressure steam sterilizer in the eastern military unit of Lanzhou Military Region. Methods A field investigation was carried out on the use of pressure steam sterilizer in 16 medical and health institutions. The on-site biological test was conducted on the sterilizing effect of the pressure steam sterilizer of the unit under test. Results The units that met the requirements of process monitoring in 2006-2009 accounted for 68.7%, 81.1% and 87.5% respectively. The qualified units of chemical monitoring of sterilization package accounted for 81.1%, 93.7% and 100% respectively. The units that meet the requirements for chemical monitoring in the center of the surgical package accounted for 56.2%, 62.5% and 100%, respectively; the units that met the requirements of the BD vacuum steam autoclave were 100% for 4 years; the units that met the requirements for biological monitoring accounted for 50%, 62.5% and 81%. In the past four years, the qualified rate of pressure sterilizer on-site biological monitoring was 100%, 81.9%, 93.3% and 96.6% respectively. Conclusion Through the supervision and inspection, the problems existing in the normative use of pressure steam sterilizer by the medical units of the eastern PLA unit in Lanzhou Military Region have basically been solved.