论文部分内容阅读
对三门峡火电厂1号炉A、B两台送风机在半年内发生的4次动叶片断裂事故进行了分析,认为产品质量不良是引起送风机损坏的根本原因,并提出了处理方案和保证风机安全运行的措施,可供同类事故参考。
This paper analyzed four faults of moving blades of two blowers A and B of Sanmenxia Thermal Power Plant No.1 in half a year and concluded that the bad quality of the products is the root cause of blower damage and proposed the treatment plan and safe operation of the blower Measures for reference for similar accidents.