【摘 要】
:
Background Blood culture contamination is a significant adverse event.The aim of this project was to evaluate the efficacy of a strict blood collection procedur
【机 构】
:
Department of Infectious Diseases,Department of Laboratory,Department of General Internal Medicine
【基金项目】
:
the Research Foundation of Nosocomial Infection Control In Peking Union Medical College Hospital,Beijing
论文部分内容阅读
Background Blood culture contamination is a significant adverse event.The aim of this project was to evaluate the efficacy of a strict blood collection procedure in reducing the blood culture contamination rate.Methods A prospectively controlled study was performed in two different medical areas in Peking Union Medical College Hospital (PUMCH) for 16 months (from May 2006 to September 2007).In test group,a strict blood collection procedure was carried out by trained nurses with the veinpuncture sites were scrupulously disinfected with 2.5% tincture of iodine plus 70% alcohol.In control group,commonly used procedure in PUMCH was performed with 0.45% chlorhexidine acetate plus 0.2% iodine.Blood culture positive results for 4 target organisms (Coagulase-negative staphylococci,Propionibacterium acnes,Corynebacterium species and Bacillus species) were further assessed by physicians from infectious department to determine whether a sample was true positive (pathogen) or false positive (contamination).Results Total 9321 blood culture collections were analyzed.The blood culture contamination rate in test group was significantly lower than that in control group (5/3177 (0.16%) vs.77/6144 (1.25%); x2=13.382,P <0.001).The most common contaminant was Coagulase-negative staphylococcus (76.83%).The average cultural time during which contaminated samples became positive was longer than that for true pathogen samples (42.0 hours vs.13.9 hours,P=0.041).Conclusion Using a strict blood collection procedure can significantly reduce blood culture contamination rate.
其他文献
Novel isosorbide derivative containing perfluorocarbon group, bi(perfluorooctanesulfonyl)isosorbide ester as chiral dopant in liquid crystal, was synthesized. C
Partial oxidation of methane (POM) co-fed with CO2 to syngas in a novel catalytic BaCo0.6Fe0.2Ta0.2O3-d oxygen permeable membrane reactor was successfully repor
In this research, a lucunary Keggin structure, [PMo2W9039]7- was selected as an efficient homogenous catalyst for degradation of an azo dye (direct blue 71) an
A mixture of guanidinium nitrate and silica sulfuric acid acts as mild and heterogeneous media for the efficient mono nitration of phenolic compounds in dichlor
Microwave assisted efficient Hantzsch reaction via four-component coupling reactions of tetrazolo [l,5-a]quinoline-4-carbal-dehyde, dimedone/cyclohexane-l,3-dio
We report a new method for detection and oxidation of adsorbed carbon monoxide (CO(ads)) generated from serine on a polycrystalline platinum ultramicroelectrode
Glutathione is an important antioxidant and has many important functions in plant development,growth and defense.Glutathione synthesis and degradation is highly
Background A new technique developed in 2002, real time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), has been one of the most i
Potassium ferrate impregnated on montmorillonite is a mild,cheap,and non-toxic reagent for the iodination of phenols, including naphthol,aromatic amines,and het
Two new sapogenins, named (205, 24R)-3β,20,21β,25-tetrahydroxy-21,24-cyclodammarane (1) and 3β-hydroxyetio-17β-dammaranic acid (2), were isolated from the a