一、炉房板的改进为防止因炉底板错位,氧化皮掉入下部搁丝槽,引起电阻丝短路,我们对炉底板接头处作了改进。图1是75kW箱式电阻炉底板的接头形式,在接头处设计了接灰槽。这样当底板错位时,掉下的氧化皮落入槽内,避免了电阻丝短路。图2是75kW箱试电组底板的另一种接头形式。接头设计成扣槽式,可使底板块与块之间牢固的结合在一起,不会因装出工件而造成错位。
First, the improvement of the furnace house To prevent the furnace floor due to dislocation, oxide scale fell into the lower wire laying groove, causing the resistance wire short circuit, we made improvements to the furnace floor connector. Figure 1 is a 75kW box-type resistance furnace floor connector form, at the joints designed to receive gray tank. In this way, when the bottom plate is dislocated, the fallen oxide falls into the groove, preventing the resistance wire from short-circuiting. Figure 2 is a 75kW box test group another form of joint joints. The joint is designed as a buckle groove, which makes the bottom plate and the block firmly combined together, and will not cause dislocation due to the work piece being installed.